RFTools · Mid game
RFTools Power Endergenic Generator Loop
The RFTools Endergenic Generator Loop is a high-yield power generation system that bounces Ender Pearls between four generators at precise tick intervals to produce massive amounts of RF/FE. While notoriously tricky to time correctly, using RFTools Sequencers and Ender Monitors makes the loop completely self-sustaining and reliable. Building this setup in the mid-game provides enough power to easily run Quarry cards inside an RFTools Builder or maintain preliminary RFTools Dimensions.
- Footprint
- 5x5x3 blocks
- Power
- ~12,000 to 20,000+ RF/t (check JEI/config for pack multipliers)
- Throughput
- ~1 Ender Pearl per 20-50 seconds (varies by pearl degradation RNG)
- Difficulty
- advanced
Flow diagram
How items, fluids and energy move through the setup, left to right.
Swipe sideways to see the whole diagram
Materials
| Item | Count |
|---|---|
| Endergenic Generator | 4 |
| Pearl Injector | 1 |
| Ender Monitor | 5 |
| Sequencer | 5 |
| Smart Wrench | 1 |
| Powercell (or Medium/Advanced Powercell) | 1 |
| Redstone Torch or Lever (for manual start) | 1 |
| Chest or Modular Storage (for Ender Pearl supply) | 1 |
| Hopper | 1 |
| Ender Pearl | 64 |
Build it step by step
1Place the Four Generators in a Square
Clear a 5x5 flat area. Place the 4 Endergenic Generators at the corners of a 3x3 square, leaving 1 air block between each generator along the edges. Every generator must have an unobstructed straight-line path of 1 block to the next generator in the loop.
2Link the Generators with the Smart Wrench
Hold your Smart Wrench and make sure it is in Link mode. Right-click Endergenic Generator 1, then right-click Generator 2 in a clockwise direction. Repeat this to link 2 to 3, 3 to 4, and finally 4 back to 1 to complete the circular path.
3Install the Pearl Injector
Place the Pearl Injector directly adjacent to or beneath Endergenic Generator 1. Attach a Hopper feeding into the Pearl Injector and put a Chest on top filled with Ender Pearls. When the Pearl Injector receives a redstone pulse, it will push a pearl into Generator 1 and automatically start the loop.
4Attach the Arrival Ender Monitors
Place one Ender Monitor directly against each of the 4 Endergenic Generators, making sure the input side of the monitor faces the generator it is reading. Open the GUI of all four monitors and set their mode to 'Pearl Arrived'.
5Position the Timing Sequencers
Place a Sequencer so that its output arrows point directly into the NEXT generator in the clockwise loop, while its input side touches the Ender Monitor of the CURRENT generator. Specifically, the monitor on Generator 1 must trigger the Sequencer pointing into Generator 2, Monitor 2 triggers the Sequencer for Generator 3, and so on around the circle.
6Configure the Sequencer Tick Delays
Open each of the four firing Sequencers and set their mode to 'Once2' (triggers once per pulse, ignoring additional pulses until finished, or 'Once1' depending on your RFTools version). Because a pearl takes 2 ticks to travel across a 1-block gap, and an Endergenic Generator peaks in efficiency at tick 10 of its charge cycle, you want the next generator to start charging before the pearl arrives. Set the 8th square (and ONLY the 8th square) in the grid to active (red) to account for the travel and monitor delay; adjust to square 7 or 9 if your server lag alters tick flight time.
7Set Up the Auto-Restart Watchdog
Place a 5th Ender Monitor against Generator 1 (or any generator) and set its mode to 'Pearl Lost'. Connect its output to a 5th Sequencer pointing into the Pearl Injector, or set up a slow repeating Timer that gets reset every time a pearl arrives. Whenever a pearl inevitably degrades and vanishes during a cycle, this monitor will detect the loss and pulse the Pearl Injector to toss in a fresh Ender Pearl.
8Connect Power Extraction and Kickstart
Place your Powercell in the center of the loop and run energy cables to all 4 Endergenic Generators (they require a tiny amount of initial RF to begin charging). Ensure the Pearl Injector has pearls, then briefly pulse the Pearl Injector with a Lever or Redstone Torch to fire the first pearl and start generating massive RF.
How it works
The Endergenic Generator works on a 20-tick internal charging cycle rather than burning fuel continuously. When an Endergenic Generator receives a redstone pulse, it switches into 'charging' mode, consuming a small amount of RF every tick to build up an internal energy surge. This surge peaks strictly at tick 10 of the charge cycle. If an Ender Pearl arrives at the generator at exact tick 10, the generator consumes the kinetic transfer, produces the maximum possible RF burst, and immediately fires the pearl toward the next linked generator on the following tick.
If a pearl arrives at a generator that is not currently charging, or arrives way before or after tick 10, the generator produces minimal power (or even loses power) and has a higher chance of destroying the pearl. By placing an Ender Monitor set to 'Pearl Arrived' on Generator A, we obtain an instant 1-tick redstone trigger the moment the pearl lands. That signal runs into a Sequencer targeting Generator B.
Because the distance between generators in our 3x3 square is 1 air block, the pearl flight time is extremely short (typically 2 ticks). Therefore, waiting for the pearl to leave Generator A before charging Generator B is too late to hit tick 10 directly on a 1-block gap unless we time the sequence across the loop's total flight cycle. In a compact 4-generator setup, the Sequencer delays the charging pulse by roughly 7 to 8 ticks so that Generator B (or the subsequent generator in the rhythmic cycle) hits its 10th charging tick at the exact tick the pearl collides with it. Every successful bounce multiplies the pearl's maturity bonus, scaling power output higher and higher until RNG eventually destroys the pearl.
Upgrades and scaling
- Infuse all 4 Endergenic Generators to 100% in an RFTools Machine Infuser using Dimensional Shards; this drastically reduces charging energy costs, increases peak RF/t output per bounce, and lowers the chance of pearl destruction.
- Replace the individual redstone components (Ender Monitors and Sequencers) with a single RFTools Control Processor running an event-based program, or use Super Circuit Maker / Integrated Dynamics for zero-footprint wiring.
- Pair the setup with an Enderman Spawner (using an RFTools Spawner and Matter Beamer) or a Mob Crusher in The End to supply infinite Ender Pearls for 24/7 operation.
Common mistakes
- Building the loop across chunk boundaries: If the Endergenic Generators sit in different chunks, minor chunk-loading desyncs or server reloads will break the 1-tick precision and drain your power bank instead of filling it.
- Forgetting to give the generators kickstart energy: Endergenic Generators consume RF while charging (ticks 1-9). If your power storage is completely empty (0 RF), the generators cannot enter charging mode and will destroy every pearl injected.
- Linking the generators in the wrong order: If you link Generator 1 to 2, 2 to 3, 3 to 4, and forget to link 4 back to 1 with the Smart Wrench, the pearl will simply vanish at Generator 4.
- Leaving a continuous redstone signal on the Pearl Injector: The Pearl Injector only fires on a rising redstone edge, and rapid-firing multiple pearls into a loop simultaneously will cause collisions that prematurely detonate both pearls.
FAQ
Why are my Endergenic Generators losing RF instead of making it?
Your Sequencer timing is off by 1 to 3 ticks. Right-click the Endergenic Generator to check its GUI statistics; it will display the 'last pearl arrival tick'. Adjust your Sequencers forward or backward by one slot until the arrival tick consistently reads 10.
How far apart should the Endergenic Generators be placed?
They can be placed with 1 to 4 air blocks between them. A 1-block gap (3x3 footprint) or 2-block gap (4x4 footprint) is ideal because longer distances keep the pearl in flight longer, requiring different Sequencer tick delays.
Why do my Ender Pearls keep disappearing after a few loops?
Every time an Endergenic Generator catches and throws a pearl, there is a small hardcoded random chance the pearl will shatter. This is normal behavior, which is why an automated Pearl Lost monitor is required to inject a replacement pearl.