OpenComputers · Power · Beginner
OpenComputers Power Converter and Networking Explained
In OpenComputers, a single Cable carries power, component connections, and network messages all at the same time. While convenient, this all-in-one behavior causes massive chaos when you try to power two computers from the same energy source, as they will accidentally hijack each other's screens and keyboards. This guide explains how to convert modded energy using the Power Converter and how to isolate your systems using Power Distributors and Relays.
What you need
- At least one assembled OpenComputers setup (Computer Case with CPU, Memory, Graphics Card, Hard Disk Drive, Lua BIOS, plus a Screen and Keyboard)
- A second Computer setup (optional, to test network and component isolation)
- An external power source (any generator or battery producing RF, FE, EU, or Mekanism Joules) and compatible energy conduits
- Power Converter
- Power Distributor
- Relay (or Switch / Access Point in older mod versions)
- Network Cards (installed inside each Computer Case you want to network)
- OpenComputers Cables
- Capacitor (optional, for energy buffer)
Step by step
1Place the Power Converter
Start by placing your external mod's power generator or energy cell near your workspace. Place the OpenComputers Power Converter directly against the generator, or connect the two using your power mod's energy conduits. The Power Converter acts as the bridge that translates external energy units (like RF, FE, or EU) into internal OpenComputers energy.
Tip: If you play without any other tech mods installed, OpenComputers typically disables power requirements by default, though you can check JEI and the mod's in-game manual to verify.
2Add a Capacitor for Stability
Place an OpenComputers Capacitor directly adjacent to your Power Converter or along the main power line. Computers draw extra bursts of energy when booting up, accessing hard drives, or running heavy components like Hologram Projectors. A Capacitor stores a local buffer of converted energy so your computers do not suddenly shut down during a momentary power spike.
Tip: Capacitors share their stored energy automatically when placed directly next to each other, allowing you to easily expand your backup battery bank.
3Power a Single Computer Directly
If you only have one computer, simply run a line of OpenComputers Cables from the Power Converter directly into your Computer Case. Place your Screen and Keyboard attached to the case (or connected via the same cable line) and press the power button inside the computer's GUI. The computer will immediately draw energy and boot up.
Tip: Notice that the Power Converter itself does not appear as a programmable component; it strictly injects power into the cable network.
4Separate Power Lines with a Power Distributor
When adding a second computer, do not connect it directly to the first computer's cable line, or both computers will try to bind to the same Screen and Disk Drive. Instead, connect the output of your Power Converter to a Power Distributor block. From the other sides of the Power Distributor, run one dedicated Cable line to Computer A, and a completely separate Cable line to Computer B.
Tip: Think of the Power Distributor as a strict firewall that lets electricity through while blocking all data and component visibility.
5Prepare Computers for Networking
Now that your two computers are safely isolated on their own power branches, they can no longer talk to each other. To allow them to exchange data without merging their component trees, open both Computer Cases and install a Network Card into an available card slot. Boot both computers back up so their operating systems recognize the new hardware.
Tip: You can verify the Network Card is active by running the 'components' command in the OpenOS shell and looking for the 'modem' entry.
6Connect Subnets Using a Relay
Place a Relay block (called a Switch or Access Point in some older versions) between the two isolated cable branches. Run a Cable from Computer A's branch into one side of the Relay, and a Cable from Computer B's branch into another side of the Relay. The Relay passes network packets sent by Network Cards between the two branches, while continuing to block component sharing.
Tip: The Relay also transfers power across its sides! However, using a dedicated Power Distributor for power and a Relay for data keeps complex server rooms much easier to troubleshoot.
7Test Your Network Isolation
Turn on both computers and check their screens to verify that each computer only displays its own boot sequence on its own monitor. Open the Lua prompt or write a quick script using the 'modem' component API to broadcast a message on a specific port from Computer A, while Computer B listens on that same port. If the message arrives while their components remain separate, your power and network architecture is complete.
Tip: If you insert a Wireless Network Card inside the Relay's internal GUI slot, it will upgrade the block into a wireless router capable of bridging wired cables with wireless robots and drones.
How it works
To master OpenComputers wiring, you must understand that a standard OpenComputers Cable transmits three completely different things simultaneously: Energy, Component visibility, and Network packets. Every contiguous line of cables forms a single local subnet. Any computer attached to that cable line can see, access, and control every single component (Screens, Keyboards, Disk Drives, Adapters) touching that same cable line.
Because of this shared visibility, plugging two computers into the same cable network causes a hardware conflict. Every component has a unique UUID address, and on boot, a computer attempts to bind to the first available Screen and Keyboard it detects on its cable line. Without isolation, Computer A might hijack Computer B's monitor, or both computers might try to render text to the same screen simultaneously.
The Power Distributor and the Relay act as filters for the three cable properties. A Power Distributor allows Energy to merge across its sides, but completely blocks Component visibility and Network packets. A Relay allows both Energy and Network packets (generated specifically by Network Cards) to pass through, while still blocking direct Component visibility. By placing these blocks between your cable lines, you share power and communication across your base while locking each computer to its own private peripherals.
Common mistakes
- Connecting multiple computers with plain cables to share a Power Converter — This merges their component networks, causing computers to steal each other's screens, keyboards, and drives. Always branch your main power line through a Power Distributor or Relay.
- Connecting a Power Converter to a Relay and expecting network messages to route without Network Cards — A Relay only forwards data packets sent via the 'modem' API. Each computer still needs an internal Network Card installed to communicate across a Relay.
- Color-coding cables touching a Power Distributor or Relay and expecting them to stay separated — While colored cables do not connect to differently colored cables, any cable touching a multi-sided block like a Power Distributor, Relay, or Computer Case will connect to all sides of that block. Leave a one-block gap or route cables carefully.
- Exceeding the component bus limit on a single cable line — Each CPU (or Server) only supports a finite number of connected components at once. If you connect dozens of Adapters and drives to one cable network, the computer will refuse to boot or ignore excess devices until you isolate the line with a Power Distributor or upgrade your CPU tier.
FAQ
Why isn't my computer requiring any power at all?
If OpenComputers does not detect a compatible energy mod installed, or if 'ignorePower' is set to true in the modpack's configuration files, all power requirements are turned off and the Power Converter is only needed for decorative purposes.
Wait, if a Relay also transfers power, do I actually need a Power Distributor?
Technically, a Relay can both distribute power and isolate components at the same time. However, Relays have a slight delay and packet buffer limit when forwarding messages, and using Power Distributors is strictly necessary when you want two systems to share power while keeping them completely air-gapped from each other's network broadcasts.
Which external energy mods work with the Power Converter?
The Power Converter natively accepts Redstone Flux (RF), Forge Energy (FE), IndustrialCraft 2 Energy Units (EU), Mekanism Joules, and Applied Energistics 2 power. Check the in-game manual or JEI for exact conversion ratios in your specific modpack.
How do I power Robots and Drones?
Mobile devices cannot tether to cables while moving. Instead, place a Charger block connected to your powered cable network and apply a Redstone signal to the Charger. Any Robot or Drone placed adjacent to (or on top of) the active Charger will have its internal battery refilled.
Use a Power Converter to translate external mod energy into OpenComputers power, then branch your cables through Power Distributors and Relays so multiple computers can share electricity and network messages without hijacking each other's screens and components.