RFTools · Power · Advanced
RFTools Power Endergenic Generator Setup: High-RF Ender Pearl Power Plant
The Endergenic Generator is one of the most rewarding and complex power sources in the RFTools family, capable of generating tens of thousands of RF per tick from a single Ender Pearl. Because it relies on precise tick-based timing rather than simple fuel burning, building one requires an understanding of redstone logic and pearl travel times. This guide walks you through the exact mechanics and provides a foolproof, self-sustaining 4-generator loop to power your late-game base and custom dimensions.
What you need
- 4x Endergenic Generators (from RFTools Power or legacy RFTools)
- 1x Pearl Injector
- 4x Ender Monitors
- 4x Sequencers (from RFTools Utility or legacy RFTools)
- 1x Smart Wrench (critical for linking and checking block distances)
- Redstone conduits, redstone dust, or RFTools Redstone Transmitters/Receivers
- High-capacity RF Powercells and energy cables
- A steady supply of Ender Pearls
- Optional: Dimensional Shards to infuse the generators for maximum efficiency
Step by step
1Lay Out the 4-Generator Diamond
Choose a flat area safely inside a single chunk to prevent chunk-unloading timing glitches. Place four Endergenic Generators in a square or diamond pattern with an exact spacing of 3 blocks between each generator in the sequence (so the pearl travels a distance of 4 blocks from center to center). Label them mentally in a clockwise circle as Generator 1, 2, 3, and 4. Place your Pearl Injector directly adjacent to Generator 1, facing into it.
Tip: If you use a spacing of 3 air blocks between generators, the Ender Pearl travel time is exactly 4 ticks, which makes configuring the Sequencers much more intuitive.
2Link the Generators in a Loop
Equip your Smart Wrench and make sure it is in linking mode. Right-click Generator 1, then right-click Generator 2 to set its destination. Next, right-click Generator 2 and then Generator 3, followed by Generator 3 to Generator 4, and finally link Generator 4 back to Generator 1 to complete the loop. You should see a visual particle beam or message confirming the connection distance.
Tip: Pay attention to the distance message in chat when linking; every block of distance equates to 1 tick of flight time for the Ender Pearl.
3Install the Ender Monitors
Place one Ender Monitor directly adjacent to each of the four Endergenic Generators, making sure the monitor's input side is facing the generator it is reading. Open the GUI of the Ender Monitor on Generator 1 and set its mode to 'Pearl Fired'. For the Ender Monitors on Generators 2, 3, and 4, open their GUIs and set them to 'Pearl Arrived'.
Tip: In newer versions of the RFTools family, ensure the flat sensor face of the Ender Monitor is pressed directly against the generator.
4Position and Wire the Sequencers
Place one Sequencer touching the output side of each Ender Monitor so it can receive its redstone pulse. Each Sequencer will control the charging phase of the NEXT generator in the loop. Run a redstone line or conduit from the output of Generator 1's Sequencer into Generator 2; wire Generator 2's Sequencer into Generator 3; wire Generator 3's Sequencer into Generator 4; and wire Generator 4's Sequencer back into Generator 1.
Tip: Keep your redstone lines completely isolated from one another so a pulse meant for Generator 2 does not accidentally trigger Generator 1.
5Program the Tick Delays
Open each Sequencer's GUI and change its mode from 'Once1' to 'Once2' (this ensures it resets immediately if a new signal arrives). The Sequencer grid has 64 squares representing 1 game tick each. Assuming a 4-tick travel time between your generators, you want the next generator to finish its 10-tick charge cycle right as the pearl arrives. For Generator 1's Sequencer (triggered on 'Pearl Fired'), set a single active redstone pulse (1 tick long) at square 1, and another 1-tick pulse at square 5 to fire it after charging. For the other three Sequencers (triggered on 'Pearl Arrived'), the timing shifts depending on travel distance; adjust the first pulse so the target generator begins charging 9 ticks before the pearl hits it, and place the second pulse exactly on the tick the pearl arrives.
Tip: Because redstone cable mods can sometimes introduce a 1-tick delay, check your generators' GUI stats while running and shift the Sequencer pulses left or right by 1 square until 'RF Gained' peaks.
6Automate the Pearl Injector
The system needs to automatically inject a new Ender Pearl only when the previous one breaks. Place an additional Ender Monitor on Generator 1 (or use an RFTools Logic Gate) to detect when the system goes idle, or set up a secondary Ender Monitor set to 'Pearl Lost' on each generator wired into a centralized Latch or Timer that triggers the Pearl Injector. For a simpler starter trigger, place a wooden button on the Pearl Injector to test your loop manually before automating the injection.
Tip: Never inject a second pearl while one is already bouncing in the loop, as the colliding signals will throw off the charge states and destroy both pearls.
7Connect Power Extraction and Test
Connect high-tier energy cables and an RFTools Powercell to all four Endergenic Generators. Note that generators actually consume a small amount of RF to hold a charge, so give the Powercell a small initial boost of power from a Coal Generator before starting. Put a stack of Ender Pearls into the Pearl Injector, press your trigger button, and watch the pearl bounce cleanly around the diamond while generating massive spikes of RF.
Tip: Use the RFTools Tablet or Smart Wrench on the generators while they are running to inspect the last cycle's RF output and confirm zero pearls are being lost prematurely.
How it works
Unlike standard generators that convert items directly into energy over time, the Endergenic Generator acts like a particle accelerator. An Ender Pearl is launched from one generator to the next in a closed loop. With every successful bounce, the pearl gains maturity, increasing the RF generated on subsequent hits until it eventually shatters due to instability.
To catch and launch a pearl efficiently, an Endergenic Generator must be switched into its 'Charging' state via a brief 1-tick redstone pulse. Once charging begins, an internal counter ticks from 1 up to 15. The sweet spot is exactly tick 10: if the flying pearl hits the generator right as it reaches charge tick 10, it yields the maximum possible RF. If the pearl arrives too early or too late, RF output drops sharply, and if the generator holds its charge past tick 15 without catching a pearl, it vents the charge and consumes RF instead.
Once the pearl arrives inside the generator, it must be fired to the next generator in the loop by sending a second 1-tick redstone pulse. Every tick the pearl sits idle inside a generator drains energy, so the ideal setup fires the pearl out on the very next tick after it arrives. By chaining Ender Monitors and Sequencers, each generator tells the next one in line to start charging well before the pearl even leaves, synchronizing the 10-tick charge ramp-up with the pearl's physical flight time through the air.
Common mistakes
- Building Across Chunk Boundaries: If your generator loop crosses a chunk border and one chunk unloads before the other, the tick timing will break instantly, causing the generators to eat your entire stack of Ender Pearls without producing power. Press F3+G to view chunk borders before building.
- Holding the Redstone Signal On: The Endergenic Generator reacts to 1-tick redstone pulses (rising edges), not continuous signals. If you leave a lever on or configure your Sequencer with a solid line of active squares instead of two individual dots, the generator will lock up and drain power.
- Forgetting Starter Power: Endergenic Generators require a small buffer of internal RF to initiate their charging phase. If your base hits zero RF, the loop cannot restart on its own without a jump-start from a secondary battery or basic generator.
- Incorrect Distance Math: The pearl travels at a fixed speed of 1 block per tick. If you move a generator even one block further away for aesthetic reasons without shifting the pulses inside your Sequencer to compensate, the pearl will miss the tick-10 window every time.
FAQ
Why are my pearls disappearing after just one or two bounces?
If pearls vanish immediately, they are either arriving at a generator that has not started charging yet, or a generator is receiving its 'fire' pulse before the pearl actually arrives. Check the generator's GUI statistics with a Smart Wrench to see if the losses are due to 'arrived while idle' and adjust your Sequencer pulses accordingly.
How does infusing the Endergenic Generator change the setup?
Infusing all four Endergenic Generators to 100% in an RFTools Machine Infuser using Dimensional Shards does not change the tick timing at all, so you do not need to reprogram your Sequencers. Instead, it dramatically increases the RF produced per hit, lowers the RF maintenance cost while charging, and slightly reduces the random chance of the pearl shattering early.
Can I build a loop with 2 or 6 generators instead of 4?
Yes, any loop of 2 or more generators works in theory, provided the total loop travel time is long enough for the first generator to complete a full 10-tick charge cycle before the pearl returns to it. A 4-generator loop spaced 3 blocks apart is widely considered the ideal balance between footprint size, material cost, and continuous tick-10 synchronization.
Why do my timings drift by 1 tick after I reload the world or server?
In some Minecraft versions and modpacks, external redstone conduits or world-tick load orders can introduce a 1-tick processing delay on startup. Using native RFTools Redstone Transmitters and Receivers or placing the Sequencers directly against the generators without intermediate cables usually eliminates this drift.
By synchronizing four Endergenic Generators with Ender Monitors and Sequencers to hit the exact 10-tick charging window, you can turn a single Ender Pearl into a massive, self-sustaining RF power plant capable of running even the most demanding RFTools dimensions.