Modular Force Field Systems (MFFS) · Addon guide · Intermediate
Classic Modular Forcefield System (Forcicium) Setup Guide
This guide walks you through setting up a full perimeter defense using the Classic branch of Modular Force Field Systems (MFFS), which relies on Forcicium and Force Energy rather than Fortron fluid. Mastering this legacy setup allows you to build an impenetrable, automated shield around your base that locks out unauthorized players and hostile mobs. You will learn how to refine raw Monazit into Force Energy, link your network via frequency cards, and configure a Security Station.
What you need
- Monazit Ore (smelted or macerated into Forcicium)
- MFFS Extractor
- MFFS Capacitor
- MFFS Projector
- MFFS Security Station (Adv. Security Station)
- MFFS Blank Cards (at least 3) and a MultiTool
- Projector Type Module (e.g., Cube, Sphere, or Containment)
- Projector Distance and Strength Upgrades
- A reliable external power source (EU, RF, or FE depending on your modpack version)
- Redstone levers or a redstone control circuit
Step by step
1Mine and Process Monazit Ore
Before placing any machines, head underground to mine Monazit Ore. Smelt the raw ore in a standard furnace to obtain Forcicium pieces, or run it through a crusher or macerator from compatible tech mods to double your yield. Forcicium is the sole fuel catalyst required to generate Force Energy in the Classic MFFS branch, so gather at least a few stacks before continuing.
Tip: Check JEI for specific processing recipes in your modpack, as some tech mods offer significant bonus outputs when grinding Monazit.
2Set Up the MFFS Capacitor
Place your MFFS Capacitor in a secure, central room of your base. This block acts as both the main battery for Force Energy (FE) and the wireless transmitter for your local forcefield network. Open its GUI and take a Blank Card, then insert it into the Power Link slot to encode it as a frequency-matched Power Link Card.
Tip: You can insert Capacity and Range upgrades into the Capacitor later to store more energy and reach distant projectors.
3Connect and Fuel the MFFS Extractor
Place the MFFS Extractor within range of your Capacitor and connect it to your base's main power grid using energy cables. Open the Extractor's GUI, place your supply of Forcicium into the top fuel slot, and insert a freshly linked Power Link Card into the card slot to bind it to the Capacitor. Finally, apply a redstone signal (like a lever) to the Extractor to start converting your electrical power and Forcicium into Force Energy.
Tip: If you are using the Capacitor right next to the Extractor, verify the link status in the GUI to ensure Force Energy is transferring and not backing up in the Extractor's internal buffer.
4Establish the MFFS Security Station
Place the MFFS Security Station near your Capacitor. Open its interface and place your MFFS MultiTool (switched to the ID/Personal ID mode) or a Blank Card into the Master slot to register yourself as the absolute system owner. Without a linked Security Station, anyone can walk up to your MFFS machines, break them, or steal your Forcicium.
Tip: Create extra Personal ID Cards for your teammates and assign them specific permission flags in the Security Station GUI, such as allowing them to bypass fields without giving them administrative rights.
5Link the Security Network
Take another Blank Card and place it into the Security Station's link slot to create a Security Link Card. Open your Capacitor's GUI and place this Security Link Card into its dedicated security slot. Because the Capacitor sits at the heart of the energy network, linking it to the Security Station automatically applies your protection rules to all connected Projectors and Extractors.
6Position and Configure the MFFS Projector
Place the MFFS Projector where you want the center of your forcefield to be. Open the Projector GUI and insert a Power Link Card (copied from the Capacitor) so it can draw Force Energy. Next, insert your chosen Projector Type Module (such as the Cube or Sphere module) into the central module slot to define the shape of your shield.
Tip: Notice how the physical texture of the Projector block changes once a valid Type Module is inserted.
7Scale and Upgrade the Field
With the Type Module installed, add MFFS Projector Distance Upgrades to increase the radius of the forcefield, and Strength Upgrades to increase the total area and thickness the projector can support. Check the Projector's GUI or your in-game guide to see exactly which slots accept distance versus strength modifiers, as this varies slightly by the shape module used. Be sure to leave at least a couple of blocks of clearance between the forcefield boundary and your base walls.
Tip: You can also install specialized upgrades like the Block Breaker upgrade (to clear terrain in the shield's path) or the Camouflage upgrade (to make the shield look like normal blocks).
8Activate the Forcefield
Apply a redstone signal directly to the MFFS Projector using a lever, or toggle the activation mode inside the Capacitor/Projector GUI if set to remote control. The Projector will immediately draw Force Energy from the Capacitor and begin generating indestructible Forcefield blocks around your perimeter. Keep an eye on the Capacitor's energy percentage to ensure your Extractor's generation rate keeps up with the Projector's upkeep cost.
Tip: Use your MultiTool in Field Teleporter mode to safely enter and exit the active shield without turning off the projector.
How it works
The Classic MFFS branch operates on a strict two-tier energy conversion logic. Standard modpack electricity (like EU, RF, or FE) cannot create forcefields on its own. The MFFS Extractor acts as a catalytic converter: it consumes standard electricity alongside physical Forcicium items to synthesize Force Energy (FE). Each piece of Forcicium provides a flat number of synthesis cycles, meaning your shield is limited by both your power grid's output and your physical mining reserves.
Once generated, Force Energy is transmitted wirelessly across a frequency network anchored by the MFFS Capacitor. Instead of running cumbersome cables to every turret and shield wall, MFFS uses frequency-encoded Power Link Cards. Every machine holding a card bound to the same Capacitor shares its energy pool and inherits its linked Security Station rules.
The Projector calculates upkeep dynamically based on volume. Every single Forcefield block resting in the world costs a small trickle of Force Energy to maintain, and destroying or blocking entities drains extra bursts of energy. If an explosion or unauthorized player breaks a forcefield block, the Projector immediately spends additional Force Energy from the Capacitor to regenerate the missing block within ticks, making the shield virtually unbreakable as long as Forcicium and power hold out.
Common mistakes
- Forgetting the Redstone Signal: Unlike many modern tech machines that run automatically, Classic MFFS Extractors and Projectors default to a redstone-controlled state and will sit completely idle until you flip an adjacent lever or change their control mode in the GUI.
- Trapping Yourself Inside Without a Master ID: If you turn on a Defense Station or a secured Projector before encoding your own Personal ID Card into the Security Station's Master slot, the system will treat you as an intruder—locking you out of the GUIs and potentially killing you.
- Outscaling Your Extractor: Putting dozens of Distance Upgrades into a Projector creates thousands of field blocks at once. If the upkeep drain exceeds your Extractor's generation rate, the Capacitor will hit zero and the entire shield will flicker off repeatedly. Add Booster upgrades to your Extractor or build multiple Extractors linked to the same Capacitor.
- Exceeding Capacitor Range: Power Link Cards have a limited wireless transmission radius. If a Projector isn't receiving power despite having a valid card, check the Capacitor GUI and install Range Upgrades.
FAQ
What is the difference between Classic MFFS (Forcicium) and the Calclavia/Voltaic MFFS (Fortron)?
Classic MFFS uses a solid item called Forcicium (from Monazit Ore) inside an Extractor to generate wireless Force Energy via Link Cards. The Calclavia and newer Voltaic versions replace this with a fluid called Fortron, generated via Coercion Derivers and Fortron Capacitors, and use a Biometric Identifier instead of a Security Station.
How do I walk through my own forcefield without turning it off?
Craft an MFFS MultiTool and switch its mode (usually by shift-right-clicking) to the Field Teleporter or Field Security bypass mode, or install a Forcefield Jammer/Access module. As long as your username is registered in the linked Security Station with bypass permissions and the tool has charge, you can teleport right through the wall.
Why can I not break my own MFFS machines with a pickaxe?
Once an MFFS machine is powered or linked to a Security Station, it becomes blast-proof and unbreakable to prevent griefing. To pick it up, you must use the MFFS MultiTool set to its Wrench mode while having administrative permissions in the Security Station.
Can one Capacitor power multiple Projectors at the same time?
Yes. You can create multiple Power Link Cards from the exact same Capacitor and insert them into several Projectors and Extractors, creating a many-to-many wireless energy grid.
By refining Monazit into Forcicium and linking an Extractor, Capacitor, Security Station, and Projector via frequency cards, you can maintain a customizable, grief-proof Force Energy shield around your base.