GregTech CEu Modern · End game

GregTech CEu Automated Assembly Line & Cleanroom Hub

This endgame infrastructure combines a spacious Sterile Cleanroom with a fully automated LuV Assembly Line to handle your most complex GregTech CEu Modern crafts. By isolating order-sensitive solid inputs and routing them alongside dedicated quadrupled fluid hatches, it completely eliminates item-clashing and manual recipe babysitting. Build this central processing complex as you break into LuV to effortlessly produce Wetware circuits, advanced motors, and fusion components on demand.

Footprint
21x15x11 blocks
Power
~32,768 EU/t (1A LuV) to 131,072 EU/t (1A ZPM) at full load
Throughput
1 high-tier component or circuit batch every 10-60 seconds (check JEI for exact recipe duration)
Difficulty
advanced

Flow diagram

How items, fluids and energy move through the setup, left to right.

Swipe sideways to see the whole diagram

LuV / ZPM EU PowerMaintenance EU/t32,768 EU/t32,768+ EU/t via 2x LuOrdered Raw ComponentsSequential Item RoutinSoldering Alloy, LubriOrdered Solid InputsMolten Polymers & SoldData Stick / Data Orb Assembled LuV/ZPM CompIntermediate Circuit CFinished High-Tier CirFinished Motors, PumpsSubstation Energy OutputHatch (LuV)POWERSuperconductor LuV CableNetworkLOGISTICSCleanroom ControllerMACHINELuV Circuit Assembler(Inside Cleanroom)MACHINEInput Crate & BufferChest ArrayINPUTConveyor Module & ItemPipe Sorting LineLOGISTICS16x ULV Input Bus(Ordered Slots 1-16)INPUT4x Quadruple Input Hatch(Fluids 1-4)INPUTData Access HatchCONTROLAssembly Line ControllerMACHINEOutput BusOUTPUTFinished ComponentStorage CrateSTORAGE
InputMachinePowerStorageLogisticsOutputControlItemFluidEnergySignal

Materials

ItemCount
Assembly Line Controller1
Cleanroom Controller1
Plasteel Casing320
Cleanroom Glass140
Filter Casing (or Sterilizing Filter Casing for UV+)81
Solid Steel Machine Casing55
Assembler Machine Casing16
Assembly Line Control Casing16
Assembly Line Grating32
Laminated Glass30
ULV Input Bus16
MV Output Bus1
IV or LuV Input Hatch (or Quadruple Input Hatch)4
LuV Energy Hatch3
Data Access Hatch (or Advanced Data Access Hatch)1
Auto-Maintenance Hatch2
Machine Hull (LuV) - For Cleanroom Passthrough4
Diode (LuV) - For Cleanroom Power Passthrough2
LuV Circuit Assembler2
Indium Tin Barium Titanium Cuprate Cable (1x or 4x)64
Electrum or Platinum Item Pipe32
Polybenzimidazole Fluid Pipe24
LuV Conveyor Module4
Tungstensteel Crate4

Build it step by step

  1. 1Erect the Cleanroom Shell

    Construct an 11x11x11 hollow cube using Plasteel Casings for the frame and Cleanroom Glass for the side walls to preserve visibility. Fill the entire top roof inner layer (9x9) with Filter Casings, placing the Cleanroom Controller in the exact center of the ceiling. Install an reinforced door for player access and an Auto-Maintenance Hatch, along with an HV or EV Energy Hatch on the exterior wall.

  2. 2Install Cleanroom Passthroughs and Assemblers

    Replace sections of the bottom-level Plasteel walls with LuV Machine Hulls and LuV Diodes; these act as legal multiblock wall blocks that safely pass items, fluids, and EU power from the outside without breaking sterility. Inside the cleanroom, place your LuV Circuit Assemblers and a high-tier Chemical Reactor directly against the interior sides of the Machine Hulls and Diodes.

  3. 3Lay the Assembly Line Foundation

    Adjacent to the Cleanroom, lay out the 16-block-long bottom layer of the Assembly Line. Place a uniform row of 16 ULV Input Buses in a straight line from front to back. Using ULV Input Buses is critical because they only have a single inventory slot, which naturally prevents different recipe items from stacking into the wrong bus.

  4. 4Complete the 16-Slice Assembly Line Structure

    Flank the 16 ULV Input Buses with Solid Steel Machine Casings on one side, and place 4 Input Hatches (plus 12 Solid Steel Machine Casings) along the other bottom edge for fluids. Build the second layer using a core row of 16 Assembler Machine Casings flanked by Laminated Glass on both sides. Build the third layer using a core row of 16 Assembly Line Control Casings flanked by Assembly Line Gratings, placing the Assembly Line Controller at the front end and the Output Bus at the back bottom slice.

  5. 5Mount Power, Data, and Maintenance Hatches

    Along the very top row of the Assembly Line (layer 4, made of Solid Steel Machine Casings), swap out casings to install two LuV Energy Hatches (allowing you to overclock to ZPM voltage), an Auto-Maintenance Hatch, and your Data Access Hatch. Position the Data Access Hatch near the front controller so you can easily swap out recorded Data Sticks and Data Orbs.

  6. 6Configure Sequential Item Routing

    Run a straight line of non-restrictive Item Pipes underneath all 16 ULV Input Buses, starting at Bus 1 ( directly under the controller) and ending at Bus 16. Attach a Tungstensteel Crate at the start of the pipe with a Conveyor Module set to import. When a precise recipe batch is dumped into the crate, items will travel down the pipe and automatically populate the single-slot ULV buses in exact sequential order from 1 to 16.

  7. 7Connect Continuous Fluid Feeds

    Hook up Polybenzimidazole Fluid Pipes to the four Input Hatches along the bottom side of the Assembly Line. Dedicate each hatch to one of the four primary assembly fluids: Soldering Alloy, Lubricant, Styrene-Butadiene Rubber, and Polybenzimidazole. Keep these hatches permanently stocked from your chemical plant so your item batches only need to worry about solid ingredients.

  8. 8Bridge the Assembly Line to the Cleanroom

    Connect the Assembly Line's Output Bus to your central storage crate, and split a filtered item pipe branch directly into the Cleanroom's passthrough Machine Hull. Any raw Wetware Boards or specialized LuV/ZPM circuit parts produced by the Assembly Line can immediately route into the sterile LuV Circuit Assemblers for final crafting.

How it works

The Assembly Line in GregTech CEu Modern is notorious for its strict positional requirements: a 15-item recipe requires each specific item stack to sit in its exact corresponding Input Bus from slice 1 to slice 15, while up to 4 different fluids must sit in distinct Input Hatches. By utilizing ULV Input Buses—which only possess a single internal inventory slot—we physically block a second item type from entering the first bus. When an ordered package of items is pushed into the main input crate in the exact order shown in JEI, the item pipe routing naturally deposits the first stack into Bus 1, overflows the second stack into Bus 2, and repeats down the 16-block spine.

Meanwhile, the Data Access Hatch holds the required Research Data Sticks or Data Orbs created inside your Research Station. Because the four standard assembly fluids (Soldering Alloy, Lubricant, Styrene-Butadiene Rubber, and Polybenzimidazole) are shared across 90% of LuV and ZPM recipes, keeping them permanently buffered in four dedicated Input Hatches removes fluid sorting from the equation entirely.

Pairing the Assembly Line directly with the Cleanroom Hub minimizes logistics delay during endgame circuit production. High-tier circuits frequently bounce back and forth between the Assembly Line (for boards, neuro-processing units, andSMD components) and a sterile Circuit Assembler. Using Machine Hulls and Diodes embedded in the Cleanroom wall allows seamless item, fluid, and LuV EU transfers without needing complex wireless grids or risking Cleanroom power starvation.

Upgrades and scaling

  • Upgrade the standard Data Access Hatch to an Advanced Data Access Hatch (or Optical Data Hatch when reaching UV) to hold vastly more Data Sticks and link directly with an High Performance Computation Array (HPCA) and Network Switch.
  • Replace the Cleanroom's normal Filter Casings with Sterilizing Filter Casings once you reach UV tier, enabling Wetware and Bio-circuit production that demands a 100% sterile environment.
  • Swap the two LuV Energy Hatches on the Assembly Line for ZPM or UV Energy Hatches as you progress, cutting recipe processing times in half with each tier upgrade.
  • Integrate an AE2 or LaserIO subnetwork onto the input crate using Blocking Mode, ensuring only one recipe's worth of ingredients enters the ULV bus line at a time to prevent cross-recipe jamming.

Common mistakes

  • Using higher-tier Input Buses (like LV or MV) on the Assembly Line without item filters; their multi-slot inventories will swallow multiple different ingredients into slice 1 and immediately break the recipe order.
  • Allowing the Cleanroom to lose power even for a single tick; it takes several minutes and significant EU to rebuild sterility back to 100%, and any recipe running inside prior to 100% sterility has a high chance of voiding your expensive LuV materials.
  • Placing the Assembly Line Output Bus on the wrong slice; it must always be placed at the very end of the bottom layer ( opposite the Controller end) based on the length of the multiblock.
  • Passing normal cables or pipes directly through the Cleanroom wall instead of using Machine Hulls and Diodes, which prevents the Cleanroom multiblock from forming.
  • Forgetting to move the Data Stick from the Scanner or Research Station into the Assembly Line's Data Access Hatch—the machine will remain idle even if all 16 items and 4 fluids are present.

FAQ

Can I build an Assembly Line shorter than 16 slices to save resources?

Yes, the Assembly Line can be built anywhere from 5 to 16 slices long depending on the maximum number of solid inputs your current recipes require (check JEI). However, building the full 16 slices immediately saves you from tearing down the back wall and relocating the Output Bus later in LuV.

Why does my Assembly Line refuse to start even though all items and fluids are in place?

Double-check three things: ensure the items are in the exact left-to-right, top-to-bottom order shown in JEI starting from the controller slice; verify that the correct researched Data Stick is inside the Data Access Hatch; and check that your Energy Hatches can supply the minimum recipe EU/t.

How many blocks can I replace with Machine Hulls and Diodes in the Cleanroom wall?

GregTech CEu Modern limits the number of special passthrough blocks (Hulls, Diodes, Hatches, and Doors) in the Cleanroom shell—always keep the majority of the shell composed of Plasteel Casings and Cleanroom Glass, and check the controller tooltip in-game if the structure fails to form.

More GregTech CEu Modern designs