Create · Mid game
Max-Level 9 Steam Boiler & FE Power Plant
This setup utilizes a Level 9 Steam Boiler from the Create mod, powered by an array of nine Blaze Burners to generate 147,456 Stress Units (SU). By pairing the rotational output with Alternators from the Create: Crafts & Additions addon, this plant converts high-tier kinetic energy into a steady stream of Forge Energy (FE) to power both your mechanical contraptions and electrical machinery. It is the ideal mid-game bridge between rotational kinetics and modern industrial power.
- Footprint
- 9x9x8 blocks
- Power
- 147,456 SU / ~1,500+ FE/t (check JEI for exact addon config)
- Throughput
- 9 Fuel items per burn cycle
- Difficulty
- intermediate
Flow diagram
How items, fluids and energy move through the setup, left to right.
Swipe sideways to see the whole diagram
Materials
| Item | Count |
|---|---|
| Fluid Tank | 36 |
| Blaze Burner | 9 |
| Steam Engine | 9 |
| Shaft | 24 |
| Mechanical Pump | 2 |
| Fluid Pipe | 8 |
| Mechanical Arm | 1 |
| Depot | 1 |
| Brass Funnel | 1 |
| Item Vault | 2 |
| Rotation Speed Controller | 1 |
| Large Cogwheel | 2 |
| Encased Chain Drive | 10 |
| Alternator | 8 |
| Modular Accumulator | 4 |
| Copper Connector | 8 |
| Copper Wire Spool | 8 |
| Hand Crank | 1 |
Build it step by step
1Place the Blaze Burners
Clear a flat 9x9 area and place a 3x3 grid of Blaze Burners one block above the ground, leaving room underneath for potential belt routing if needed. Ensure all nine burners have captured Blazes inside them, as empty burners will not provide the active heat required for a Level 9 boiler.
2Construct the Boiler Tank
Directly on top of the 3x3 Blaze Burner grid, place a 3x3x4 multiblock of Fluid Tanks (36 tanks in total). They will automatically merge into a single large tank capable of supporting nine levels of size for the boiler calculation.
3Set Up the Water Supply
Dig a 3x1 infinite water trench near the base of the boiler and place two Mechanical Pumps drawing from the center block into the Fluid Tank using Fluid Pipes. The pumps will need to spin at roughly 180 RPM total combined speed to satisfy the water demand of a Level 9 boiler.
4Install the Steam Engines
Attach nine Steam Engines along the sides of the Fluid Tank multiblock, leaving at least one block of space around their fronts. Right-click the extended piston rods of each Steam Engine with a Shaft; the shafts will automatically snap into place perpendicular to the engine.
5Link the Output Shafts
Place three columns of three Steam Engines on three sides of the tank, or group them in rows so their output shafts align. Connect all nine engine shafts together using Encased Chain Drives and additional Shafts so they form one unified kinetic network.
6Automate Fuel with a Mechanical Arm
Place an Item Vault nearby with a Brass Funnel outputting fuel onto a Depot. Before placing the Mechanical Arm, right-click the Depot to set it as an input, then right-click all nine Blaze Burners to set them as outputs, and finally place the Arm within a 4-block reach of all targets.
7Add Speed Control and Alternators
Route the main unified shaft from the Steam Engines into a Rotation Speed Controller paired with a Large Cogwheel, and set the controller to 256 RPM. From the high-speed output, branch out using Encased Chain Drives to power your array of Alternators, and route a small secondary 180 RPM shaft line back to your water pumps and Mechanical Arm.
8Wire the Electrical Output
Place your Modular Accumulators near the Alternators to serve as a battery bank. Attach Copper Connectors to the Alternators and the Accumulator, then link them using Copper Wire Spools, and finally use the Hand Crank on the water pumps to kickstart the entire self-sustaining loop.
How it works
Create's Steam Boilers operate on a strict equilibrium between three values: Tank Size, Water Supply, and Heat. Each Level requires 4 Fluid Tanks, a baseline amount of pumped water per tick, and 1 level of active heat. By building a 3x3x4 tank (36 blocks) over 9 fueled Blaze Burners, both the Size and Heat metrics reach Level 9. Once the Mechanical Pumps spin fast enough to meet the Level 9 water threshold, the boiler reaches maximum efficiency for its footprint without requiring expensive Blaze Cakes.
Each Steam Engine attached to the tank can extract up to 16,384 SU, which corresponds to 1 boiler level. Because this setup reaches Level 9, we must attach exactly 9 Steam Engines to extract the full 147,456 SU generated. Steam Engines naturally output this massive torque at a slow 64 RPM, which is inefficient for Create: Crafts & Additions Alternators that scale their FE output and efficiency with higher rotational speeds.
To bridge this gap, all nine engine outputs are combined into a single kinetic line and fed into a Rotation Speed Controller bumped up to the maximum 256 RPM. While quadrupling the speed quarters the available Stress capacity on the high-speed side, it allows each Alternator to run at peak electrical generation. A tiny fraction of the generated SU is tapped off before the Alternators to keep the water pumps and the fuel-feeding Mechanical Arm running indefinitely, making the plant 100% self-sustaining as long as the Vault has fuel.
Upgrades and scaling
- Upgrade to a Level 18 Mega-Boiler by stacking 4 more layers of Fluid Tanks (72 total), doubling the water pump speed, attaching 9 more Steam Engines, and feeding the Blaze Burners with Blaze Cakes instead of standard fuel to reach 294,912 SU.
- Replace the charcoal/coal Vault with an automated Create tree farm or a Lava dripstone cauldron array feeding Buckets of Lava via the Mechanical Arm for truly infinite, zero-maintenance fuel.
- Attach a Threshold Switch to the Modular Accumulator and link it via Redstone Link to a Clutch on the Mechanical Arm, pausing fuel consumption entirely whenever your FE battery bank is 100% full.
Common mistakes
- Forgetting to right-click the targets with the Mechanical Arm in hand before placing it down on the ground; you cannot configure an Arm's inputs and outputs after it is already placed.
- Under-speeding the Mechanical Pumps, which causes the boiler's water bar to drop below Level 9 and severely bottlenecks your total SU output.
- Placing the Steam Engine shafts in conflicting rotational directions; if two engines on opposite sides of the tank are chained together while spinning against each other, the shafts will instantly break.
- Starving the water pumps of SU when adding too many Alternators; always calculate your Alternator stress draw via Engineer's Goggles or JEI so the system does not overstress and shut off its own water supply.
FAQ
How does the system start if the water pumps are powered by the boiler itself?
You must kickstart the system manually. Attach a Hand Crank or a temporary Water Wheel to the Mechanical Pump shaft and spin it for a few seconds until water enters the hot tank; once steam builds, the engines will take over and power the pumps automatically.
Why use a Mechanical Arm instead of Mechanical Belts and Funnels for the Blaze Burners?
Because the Blaze Burners are packed tightly in a 3x3 grid, routing belts and funnels to reach the center burner is bulky and awkward. A single Mechanical Arm can reach all 9 burners cleanly from the diagonal corner.
How many Alternators can this Level 9 setup run at once?
Subtract roughly 4,000 SU for the pumps and Mechanical Arm from the 147,456 SU total, then divide the remaining SU by the stress impact of one Alternator at 256 RPM (check JEI or wear Engineer's Goggles, as modpack configs often alter Alternator stress values).