Tech Reborn · End game
Tech Reborn Self-Sustaining Fusion Reactor Power Plant
This endgame setup creates a completely self-sustaining Fusion Reactor power plant in Tech Reborn. By processing infinite water through a dedicated array of Industrial Electrolyzers and Industrial Centrifuges, it continuously refines and feeds Deuterium and Tritium into the toroid reactor. Once jumpstarted, the plant generates a massive net surplus of energy while powering its own fuel production loop.
- Footprint
- 21x21x7 blocks
- Power
- Net output of several thousand E/t (check JEI for exact pack recipe values)
- Throughput
- Continuous 1:1 Deuterium and Tritium fuel supply
- Difficulty
- advanced
Flow diagram
How items, fluids and energy move through the setup, left to right.
Swipe sideways to see the whole diagram
Materials
| Item | Count |
|---|---|
| Fusion Control Computer | 1 |
| Fusion Coil | 28 |
| Industrial Electrolyzer | 6 |
| Industrial Centrifuge | 20 |
| Superconductor Cable | 32 |
| Glass Fiber Cable | 64 |
| Interdimensional SU | 1 |
| Adjustable SU | 1 |
| HV Transformer | 2 |
| Overclocker Upgrade | 64 |
| Transformer Upgrade | 26 |
| Empty Cell | 256 |
| Hopper | 32 |
| Quantum Tank | 2 |
Build it step by step
1Construct the Fusion Toroid
Place the Fusion Control Computer in the center of your designated area. Right-click the computer and click the 'H' button to project the holographic multiblock guide. Place all 28 Fusion Coils in the exact ring pattern shown by the hologram until the interface confirms the structure is complete.
2Install High-Tier Energy Storage
Run Superconductor Cables from the output faces of the Fusion Control Computer into an Interdimensional SU or Lapotronic SU. Place an Adjustable SU branching off this main storage line to act as a dedicated battery for your fuel processing machines, ensuring the main grid never drains the fuel loop.
3Build the Electrolyzer Bank
Set up a row of 6 Industrial Electrolyzers and connect them to a continuous water supply using fluid pipes or pumps. Configure their internal side-IO slots to accept water and Empty Cells from the top, and push Hydrogen Cells out the back.
4Set Up Primary Centrifuges (Deuterium)
Place 16 Industrial Centrifuges to process the Hydrogen Cells from the Electrolyzers. Every 4 Hydrogen Cells centrifuge into 1 Deuterium Cell and 3 Empty Cells. Route the Empty Cells back to the Electrolyzer input buffer, and split the Deuterium Cells evenly between the reactor and the next centrifuge stage.
5Set Up Secondary Centrifuges (Tritium)
Place 4 Industrial Centrifuges to receive half of the produced Deuterium Cells. Every 4 Deuterium Cells centrifuge into 1 Tritium Cell and 3 Empty Cells. Send these Tritium Cells directly to the Fusion Control Computer and recycle the Empty Cells back to the start of the loop.
6Balance Speeds with Upgrades
Industrial Centrifuges are very slow by default compared to the Fusion Reactor's burn rate. Insert Overclocker Upgrades and Transformer Upgrades into both banks of Centrifuges and the Electrolyzers until fuel production slightly exceeds the reactor's consumption rate (check JEI for exact tick durations).
7Ignite the Reactor
Allow the processing machines to completely fill the Fusion Control Computer's input slots with Deuterium Cells and Tritium Cells. Supply the massive initial ignition energy required (check JEI for the exact Start-E cost) from an external pre-charged energy storage unit into the computer. Once the ignition bar fills, the reaction will begin and become self-sustaining.
How it works
The core logic of this power plant revolves around the 4:1 compression ratio of hydrogen isotopes in Tech Reborn. An Industrial Electrolyzer breaks down water and Empty Cells into Hydrogen Cells, Compressed Air, and Oxygen. Because the reactor requires both Deuterium and Tritium in a 1:1 ratio, and Tritium is made from 4 Deuterium, your primary Centrifuge bank must produce five times as much Deuterium as the reactor directly consumes. Four-fifths of that Deuterium goes to the secondary Centrifuge bank to become Tritium, while one-fifth goes straight into the Fusion Control Computer.
Cell recycling is critical for full automation. Every time 4 Hydrogen Cells are centrifuged into 1 Deuterium Cell, 3 Empty Cells are left over. Similarly, the Fusion Reactor outputs Heliumplasma Cells (and Empty Cells once processed or extracted). By using filtered item logistics or Tech Reborn's built-in machine slot configuration to route all Empty Cells back to the Electrolyzers, and venting excess Oxygen and Compressed Air into trash cans or Quantum Tanks, the system never jams.
Power management is separated into two grids using an Adjustable SU and HV Transformers. The Fusion Reactor outputs extreme voltage that will explode standard machines, so Superconductor Cables must bridge the reactor to high-tier storage first. Stepping down a fraction of that power through transformers to run the overclocked Centrifuges and Electrolyzers guarantees the fuel line stays active even if you completely drain your main base battery.
Upgrades and scaling
- Expand the fusion ring size via the Fusion Control Computer interface up to the maximum allowed multiplier to massively boost energy output per tick at the cost of requiring more Fusion Coils.
- Replace vanilla hoppers or basic pipes with an AE2 or Refined Storage sub-network to handle cell routing and byproduct voiding cleanly in a smaller footprint.
- Harvest the outputted Heliumplasma Cells instead of voiding them if your modpack includes cross-mod integration or advanced recipes that utilize helium.
Common mistakes
- Connecting standard cables directly to the Fusion Control Computer instead of Superconductor Cables, which causes the cables to immediately burn up from over-voltage.
- Letting the Fusion Reactor run out of fuel for even a single tick; if the reaction stops, you must pay the massive multi-million energy ignition cost all over again.
- Adding too many Overclocker Upgrades to the Industrial Centrifuges without adding Energy Storage Upgrades, causing the machine's internal power buffer to be smaller than a single tick's operation cost.
- Forgetting to void or store excess Oxygen and Compressed Air from the Industrial Electrolyzers, which eventually fills the output slots and halts Hydrogen production.
FAQ
Why is my Fusion Control Computer not forming the multiblock?
Use the hologram toggle ('H' button in the GUI) to check for misplaced blocks. Ensure all 28 Fusion Coils are placed at the exact same Y-level as the computer and that no cables or torches are obstructing the inner ring.
How do I provide the initial ignition power if the reactor isn't running yet?
Charge a Lapotronic SU or a bank of MFSUs using mid-game generators like Diesel Generators, Thermal Generators, or Solar Panels, then connect them directly to the Fusion Control Computer until the ignition bar reaches 100%.
Do I need to use cells, or can I pipe fluids directly into the machines?
Depending on your exact version of Tech Reborn, many recipes strictly require Empty Cells inside the recipe slots, while newer versions allow fluid tank input. Check JEI in your specific pack to see if fluid variants of Deuterium and Tritium are supported.