XNet · Power · Beginner
How to Build a Lag-Free Power Grid with XNet
In this guide, you will learn how to build an ultra-efficient, centralized power distribution grid using XNet to send Forge Energy (FE) or Redstone Flux (RF) from your generators to all of your machines. Unlike traditional energy conduits that constantly calculate paths and cause server lag, XNet uses a single Controller and lightweight cables to move power instantly across huge distances. By the end, you will have a self-sustaining network that powers your entire base and keeps its own brain running smoothly.
What you need
- 1 XNet Controller
- Connectors (Blue, or any matching color; Advanced Connectors for higher transfer limits)
- Network Cables (matching the color of your Connectors)
- At least one Forge Energy (FE) or RF generator
- Any energy-consuming machines (furnaces, crushers, etc.)
Step by step
1Place the XNet Controller
Start by placing your XNet Controller in a convenient, accessible spot near your power generation area. This block serves as the central brain for your entire power grid and is where you will configure all energy routing. Keep in mind that the Controller itself requires a small amount of constant power to function, which we will hook up in the coming steps.
Tip: Place the Controller at eye level so you can easily right-click it to manage your network as your base expands.
2Attach Connectors to Machines and the Controller
Place a Connector directly against your power generator, another Connector against each machine you want to power, and one final Connector directly against the XNet Controller itself. Connectors are the actual interface blocks that pull and push energy into adjacent blocks. Make sure all the Connectors you use for this network are the exact same color, such as Blue.
Tip: You can name your connected blocks inside the Connector's GUI or notice their coordinates to make identifying them inside the Controller much easier later.
3Link Everything with Network Cables
Run Network Cables of the matching color between all of your placed Connectors so they form one continuous, unbroken line. Network Cables cannot interact with machines on their own; they simply bridge the gap between your Connectors and the Controller. Once linked, the Controller will automatically detect every machine attached to a Connector on that cable line.
Tip: XNet offers four cable colors (Blue, Yellow, Red, Green) that will not connect to each other, allowing you to run separate networks side-by-side without them merging.
4Jumpstart and Create an Energy Channel
Right-click the XNet Controller to open its interface. If it has no power yet, temporarily place a small battery, energy cell, or survival generator directly touching the Controller to give it an initial charge. In the GUI, look at the eight vertical channel columns along the top, click on Channel 1, select 'xnet.energy' from the dropdown list, and click 'Create' to establish your power grid channel.
5Configure the Generator to Extract Energy
Look at the list of connected blocks on the left side of the Controller GUI and locate your power generator. Click inside the Channel 1 column directly across from your generator's name, then click the 'Create' button in the bottom panel to add a connection. Change the mode toggle in the bottom panel from 'Ins' (Insert) to 'Ext' (Extract) so XNet knows to pull energy out of the generator.
Tip: Notice the transfer rate limit box in the bottom right panel; check your modpack's JEI or in-game manual (The One Probe / RFTools manual) for the exact RF/t cap of standard versus Advanced Connectors.
6Make the Controller Self-Sustaining
Find the XNet Controller itself in the left-hand block list (it appears there because you placed a Connector directly on it). Click inside the Channel 1 column next to the Controller's entry and click 'Create' at the bottom. Leave its mode set to 'Ins' (Insert) and set its 'Priority' box to a high number like 10. This ensures the Controller always feeds itself power first before distributing the rest to your factory, allowing you to remove your temporary jumpstart battery.
Tip: Keeping the Controller at the highest priority prevents your entire factory network from shutting down during a brownout if your machines suddenly demand more power than you generate.
7Distribute Power to Your Machines
For every other machine in the list that needs power, click in the Channel 1 column next to its name and click 'Create'. Leave their mode set to the default 'Ins' (Insert) and leave their Priority at 0 (or adjust priorities if certain machines, like life-support or Quarry systems, are more important than others). Your power grid is now fully operational and distributing energy across your base!
Tip: You still have 7 empty channels left in this single Controller, meaning you can now route items, fluids, and logic along the exact same cables without placing a single new block.
How it works
Traditional energy pipes in many tech mods treat every single cable segment as a Tile Entity (or Block Entity) that must constantly tick, check its neighbors, and calculate energy saturation every twentieth of a second. When you build a massive base with hundreds of cable segments, this creates heavy CPU overhead and lowers your server's ticks-per-second (TPS).
XNet completely solves this problem by making its Network Cables 'dumb' blocks—they are not Tile Entities at all, meaning a cable 10,000 blocks long creates virtually zero lag. Instead, only the Connectors and the XNet Controller perform calculations. The Controller simply maintains a direct list of every valid Connector on the line and teleports the energy directly from the extracting Connector to the inserting Connector in a single operation.
Because the Controller does all the work, each Connector has an internal energy throughput ceiling per tick. Standard Connectors handle early-to-mid-game power requirements easily, while Advanced Connectors increase the maximum RF/FE transfer rate significantly and allow you to access any side of a machine remotely. Furthermore, because the Controller requires a tiny operational power cost per active channel and operation, routing an Insert connection back into the Controller itself creates a closed, self-powering loop.
Common mistakes
- Using Network Cables without Connectors: Players often try to press Network Cables directly against a machine expecting them to connect. Cables only link Connectors together; you must always place a Connector against any block you want to interact with.
- Forgetting to power the XNet Controller: If the Controller runs out of internal energy, the entire network freezes, stopping the generator from sending power to the Controller. Always give the Controller a Connector on the energy channel with the highest priority.
- Leaving the Generator on 'Insert' mode: When you create a new connection in a channel, XNet defaults to 'Ins' (Insert). If your machines aren't receiving power, double-check that your generator or battery bank is explicitly switched to 'Ext' (Extract).
- Bottlenecking high-tier generators with standard Connectors: If your generator produces massive amounts of power per tick and your machines are still starving, you have likely hit the per-Connector transfer rate cap. Upgrade both the generator's Connector and the high-drain machine's Connector to Advanced Connectors.
- Mixing cable colors by accident: A Blue Network Cable will never connect to a Yellow Connector. Keep your colors uniform for a single network, or use different colors intentionally to keep separate grids from merging.
FAQ
Why do my Network Cables have no transfer limit listed in JEI?
Because Network Cables do not actually hold or transport energy themselves! The transfer rate limit is determined entirely by the Connectors attached to your machines. Check the standard Connector and Advanced Connector tooltips or the in-game manual for your modpack's exact RF/t limits.
Can I run items and fluids through the exact same cables powering my machines?
Yes! That is the biggest strength of XNet. Simply click on Channel 2 in your Controller, set it to 'xnet.item' or 'xnet.fluid', and use the exact same Connectors already attached to your machines to pull out finished products or pump in water.
What happens if my network runs out of power completely?
If a blackout occurs and the Controller's internal buffer empties, it cannot run the energy channel to pull power from your generators once they turn back on. You will need to briefly touch a charged battery or coal generator directly against the Controller to jumpstart the loop.
When should I upgrade to Advanced Connectors?
You should upgrade to Advanced Connectors when a machine requires more FE/t than a standard Connector can insert, or when a generator outputs more than a standard Connector can extract. Youonly need to upgrade the specific Connectors experiencing the bottleneck, not every Connector on the network.
By combining non-ticking Network Cables with a self-powered XNet Controller, you can distribute RF/FE across your entire base instantly while keeping your world completely free of conduit lag.