Tech Reborn · Troubleshooting · Beginner
Tech Reborn Troubleshooting: Fixing Machine Explosions, Multiblock Failures & Power Drops
Tech Reborn brings classic industrial mechanics to Minecraft, meaning one wrong cable connection or pickaxe swing can instantly destroy your expensive setup. This troubleshooting guide will teach you how to prevent over-voltage explosions, properly align directional energy storage, safely relocate machines, and fix unresponsive multiblock structures. Mastering these core mechanics will save your resources and keep your automated factory running smoothly.
What you need
- Tech Reborn Wrench
- Insulated Copper Cable, Insulated Gold Cable, or higher tier cables
- LV Transformer, MV Transformer, or HV Transformer
- Battery Box, CESU, MFE, or MFSU
- Machine Casings (Standard, Reinforced, or Advanced) for multiblocks
- Overclocker Upgrades and Transformer Upgrades
Step by step
1Safely Dismantle Machines with a Wrench
Never use a pickaxe to break a Tech Reborn machine, or it will revert into a basic Machine Frame, destroying all internal components. Instead, craft a Tech Reborn Wrench and hold Shift (Sneak) while right-clicking the machine you want to move. The machine will pop off the ground intact and keep its upgrades or internal inventory.
Tip: Regular right-clicking with a Wrench without holding Shift simply rotates the machine's facing direction.
2Align Directional Battery Output Dots
Energy storage blocks like the Battery Box, CESU, MFE, and MFSU have five sides for input and only one specific face with an orange or yellow dot for output. If your machines are not receiving power, examine your storage block to locate this single output dot. Hold your Wrench and right-click on the side of the storage block where your power cable is attached to move the output dot to that face.
Tip: Your power generator cables must connect to the blank sides of the battery, never the side with the dot.
3Prevent Over-Voltage Machine Explosions
Before connecting any machine to a power line, hover over the machine in your inventory or check JEI to see its Maximum Input voltage tier (such as Low, Medium, or High). If you connect a Low Tier machine like a basic Electric Furnace directly to a Medium Tier power source like a CESU, the machine will instantly explode. Place an LV Transformer between the power source and the machine to step the voltage down safely.
Tip: Alternatively, you can insert a Transformer Upgrade directly into the machine's upgrade tab to allow it to accept the next voltage tier.
4Configure Transformer Step-Down Direction
Transformers also use directional dots to control power flow. When stepping power down from high to low voltage, connect your higher-tier power source to the single face that has the prominent three-dot or single large input marker. Connect your lower-tier cables and machines to any of the other five single-dot output faces.
Tip: Use a Wrench to rotate the high-voltage input face toward your main power line before connecting the cables.
5Diagnose 'Incomplete' Multiblock Structures
If your Industrial Blast Furnace, Vacuum Freezer, or Industrial Grinder displays an 'Incomplete' status in its GUI, press the 'H' button inside the machine's interface. This activates a translucent hologram in the world showing the exact placement of the required Standard, Reinforced, or Advanced Machine Casings. Walk around the structure to spot any mismatched blocks, and check that the center matches the exact air or fluid requirements.
Tip: The Industrial Blast Furnace requires two Lava source blocks inside the hollow center column to reach its full heat capacity and validate properly.
6Check Machine Casing Alignment
Multiblock controllers require a very specific orientation relative to their casing grid. Ensure the controller block itself is placed in the exact spot shown by the hologram, usually centered on the bottom edge or direct middle of the structure, not on a corner. Break any torches, wires, or snow layers sitting inside the 3x3 or hollow areas of the multiblock, as even invisible light blocks can invalidate the structure.
Tip: Right-click the multiblock controller after placing the final casing to force it to re-scan the area.
7Fix Mid-Operation Power Drops
If a machine starts processing an item, stops halfway, and loses all progress, your power supply cannot keep up with the machine's continuous energy draw. This usually happens after installing too many Overclocker Upgrades, which multiply energy consumption exponentially. Open the machine's upgrade tab and remove one or two Overclocker Upgrades, or upgrade your cables and battery buffer to supply higher amperage.
Tip: Check the machine tooltip or in-game guide to see the exact energy cost per tick, and compare it against your cable's transfer limit.
How it works
Tech Reborn utilizes a packet-based energy system Divided into strict voltage tiers: Low (LV), Medium (MV), High (HV), and Extreme (EV). Every energy source emits packets of a fixed size based on its tier. When a cable delivers a packet to a machine, the machine compares the incoming packet size to its internal maximum input threshold. If the incoming packet exceeds that threshold even for a single tick, the mod triggers an explosion event and deletes the block.
Cables and storage blocks manage the flow of these packets using directional logic. Storage blocks act as diodes, absorbing packets from five faces and emitting a single regulated packet stream from the dotted output face. Transformers intercept large packets on their high-voltage input face and split them into multiple smaller packets on their five output faces, ensuring downstream machines receive safe power sizes.
Multiblock validation relies on a strict coordinate scan offset from the facing direction of the main controller block. When you open the GUI, the controller checks the exact block IDs in a predefined 3D bounding box behind it. If a single block is a wrong casing tier, or if an expected air block is replaced by a torch or cable, the boolean check fails and locks the machine.
Common mistakes
- Breaking machines with a pickaxe out of habit: Always keep a Tech Reborn Wrench on your hotbar; breaking a machine with any pickaxe strips it down to a basic Machine Frame.
- Using uninsulated cables near walkways: High-tier uninsulated cables will electrocute and damage you on contact; always craft them with rubber to create Insulated cables.
- Spamming Overclocker Upgrades: Installing four Overclockers in a basic machine increases its power draw massively, draining your Battery Box instantly and stalling all factory progress.
- Connecting high-tier cables to low-tier machines thinking the cable limits the voltage: Cables only have a maximum capacity; they do not step down voltage. A Gold Cable connected to an MFE will still send High Voltage packets and blow up an LV machine.
FAQ
Why did my cable burn up and disappear?
Every cable tier has a maximum transfer limit. If you run High Voltage power from an MFE through a Low Tier Insulated Copper Cable, the cable will overheat, emit smoke particles, and melt. Upgrade the wire to an Insulated Gold or HV Cable.
Can I rotate a multiblock controller so the casing structure is above it?
No, multiblock controllers only scan horizontally behind or around their fixed orientation. Always follow the built-in 'H' hologram preview for the exact controller position.
Why is my Industrial Blast Furnace formed, but refusing to smelt Silicon or Steel?
Every Blast Furnace recipe has a minimum Heat requirement shown in JEI. Standard Machine Casings only provide base heat; you must upgrade the structure with Reinforced or Advanced Machine Casings and add two Lava source blocks inside the center to reach higher heat thresholds.
How do I save a machine if I accidentally wired it to high voltage?
Once the packet reaches the machine, the explosion is instant. Always wire and configure your Transformers first, and connect the machine's cable last, or drop a Transformer Upgrade into the machine before hooking up the power line.
By matching your voltage tiers with Transformers, aligning battery output dots with a Wrench, and using the built-in multiblock hologram, you can build a safe, explosion-free Tech Reborn factory.