Tech Reborn · Explained · Beginner
Tech Reborn Power System Explained: Voltage Tiers, Cables & Transformers
In Tech Reborn, connecting the wrong power cable to a machine can instantly destroy your hard-earned workshop in a fiery explosion. This beginner-friendly guide explains how the mod's Energy (E) and packet-based voltage tiers work so you can safely generate, step down, and distribute power. By the end, you will know how to select the right insulated cables and configure Transformers to keep your factory running smoothly without a single blowout.
What you need
- A basic power generator (such as a Solid Fuel Generator)
- Insulated Copper Cables, Insulated Gold Cables, and Insulated HV Cables
- Energy storage blocks (Battery Box, MFE, or MFSU)
- Transformers (LV Transformer, MV Transformer, HV Transformer)
- A Tech Reborn Wrench (to safely rotate and dismantle machines)
- Basic processing machines (such as an Electric Furnace or Grinder)
- Rubber (crafted from Sap extracted from Rubber Trees using a Treetap) for cable insulation
Step by step
1Inspect Machine Voltage Ratings in Tooltip
Before placing any blocks, open your inventory or recipe viewer (such as JEI or REI) and hover your cursor over your generator and your target machine. Look at the tooltip to identify the 'Max Input' for machines and 'Max Output' for generators, which correspond to Low (LV), Medium (MV), High (HV), or Extreme (EV) voltage tiers. Matching these ratings is the fundamental rule of Tech Reborn: a machine's Max Input must always be equal to or greater than the power packet size it receives.
Tip: Hold Shift while hovering over any Tech Reborn block in your inventory to reveal detailed energy statistics, including internal buffer capacity and exact transfer rates.
2Build a Safe Low Voltage (LV) Network
Place down a Solid Fuel Generator and an Electric Furnace a few blocks apart. Connect them using Insulated Copper Cables, or Tin Cables for very low-tier applications. Because the Solid Fuel Generator outputs Low Voltage and the Electric Furnace accepts Low Voltage, inserting coal into the generator will safely power the furnace with zero risk of overheating or exploding.
Tip: Always craft Insulated cables using Rubber rather than laying down bare wires, as uninsulated cables will electrocute you if you walk into them while power is flowing.
3Add an Energy Buffer (Battery Box)
Generators only produce power while burning fuel, which can waste resources if your machines are idle. Break one of the cables between your generator and machines, and place a Battery Box in that spot. Notice the textures on the sides of the Battery Box: five sides have a single dot (inputs) and one side has a special output face. Point the single output face toward the cable leading to your machines, and connect your generator to any of the other five sides.
Tip: Use a Tech Reborn Wrench and right-click on the desired side of a Battery Box or Transformer to change which direction the output face points.
4Upgrade to Medium Voltage (MV) Storage
As your base grows, a Battery Box will no longer hold enough energy, requiring you to upgrade to an MFE (Medium Voltage storage). Place your MFE down and connect it using Insulated Gold Cables, which are rated for Medium Voltage. Do not connect your basic LV machines (like the Electric Furnace or Grinder) directly to the output of the MFE yet, because the MFE outputs Medium Voltage packets that will instantly destroy Low Voltage machines.
5Install an LV Transformer to Step Down Power
To safely feed power from your MFE to your basic machines, craft and place an LV Transformer directly in the path of the Insulated Gold Cable coming from the MFE's output face. Look closely at the LV Transformer's sides: one face has a larger, three-dot or distinct high-tier socket (the MV input), while the other five faces have single-dot sockets (the LV outputs). Rotate the Transformer with your Wrench so the single special MV input face points directly toward the MFE's incoming Gold Cable.
Tip: Think of the Transformer faces in terms of power density: the single special face handles the single high-voltage source, while the five identical faces distribute stepped-down low voltage to multiple lines.
6Branch Out to Your LV Machines
Now that the LV Transformer is receiving Medium Voltage on its high-tier face, it will automatically split each MV packet into multiple safe LV packets. Attach Insulated Copper Cables to any of the five low-voltage output faces on the LV Transformer. Run these Copper Cables directly into your Electric Furnace, Grinder, Alloy Smelter, and Extractor. Your machines will now draw abundant power from the MFE without exploding.
7Scale Up to High and Extreme Voltage (HV & EV)
When you progress to an MFSU (High Voltage storage) or advanced generators like the Diesel Generator or Fusion Control Computer, repeat the exact same stepping-down logic. Connect an MFSU to an MV Transformer using Insulated HV Cables (crafted with Refined Iron and two layers of rubber). Then, run Insulated Gold Cables from the MV Transformer into an LV Transformer, and finally Copper Cables to your basic machines, creating a cascading power grid.
Tip: Alternatively, you can craft Transformer Upgrades and insert them directly into the upgrade slots inside your basic machines, allowing an LV machine to safely accept MV or HV power directly without external Transformer blocks.
How it works
Unlike many modern tech mods that treat energy as a continuous fluid stream, Tech Reborn uses a discrete 'packet' system inspired by classic IndustrialCraft. Power moves through cables in individual bundles of Energy (E). Each Voltage Tier defines the maximum size of a single packet: Low Voltage (LV, typically up to 32 E/t), Medium Voltage (MV, up to 128 E/t), High Voltage (HV, up to 512 E/t), and Extreme Voltage (EV, up to 2048 E/t). Note that exact numbers can be tweaked by modpack authors, so always verify the tooltip values in JEI.
Crucially, machines and cables care about the size of each individual packet, not the total number of packets passing through per tick. For example, if you connect four Solid Fuel Generators to a single Insulated Copper Cable line, they send four separate LV packets per tick down the wire. Because no single packet exceeds the LV limit, your basic machines and Copper Cables are completely safe, while the machine actually receives four times the total energy per tick.
However, if an MFE sends a single Medium Voltage packet down that same Copper Cable into an LV machine, the packet size exceeds the threshold. The Copper Cable will burn up into smoke, and if the packet reaches the machine, the machine block will violently explode. An LV Transformer solves this by taking one large MV packet on its high-tier input face and converting it into four separate LV packets on its output faces, maintaining the exact same total energy flow while keeping individual packet sizes safe.
Common mistakes
- Breaking machines with a Pickaxe: Never use a regular pickaxe to move a misplaced Generator, Battery Box, or Transformer, as it may break into a basic Machine Frame or get destroyed. Always use a Tech Reborn Wrench (Shift + Right-Click) to safely pick up the intact block.
- Reversing Transformer orientation: Pointing the five low-voltage faces toward your high-voltage power source will block power flow or cause a burnout. Always make sure the single distinct high-tier face points toward the higher voltage source when stepping power down.
- Using uninsulated cables near walkways: Laying down bare Copper, Gold, or HV cables saves rubber early on, but touching them while power is actively transferring deals rapid electric damage. Always insulate your cables.
- Connecting new machines before placing the Transformer: If you wire up a live MFE or MFSU to a cable line that is already touching an LV machine, the machine will explode the exact tick the circuit closes. Always build and orient your Transformers before connecting the power source.
FAQ
Can I use a Transformer in reverse to step power UP from LV to MV?
Yes. If you apply a constant Redstone signal (such as placing a Lever on the block and flipping it on) to a Transformer, it reverses its behavior. It will accept low-voltage packets on its five normal faces, combine them, and output high-voltage packets from its single special face.
Why are my cables melting and disappearing with smoke particles?
You are sending a voltage packet through a cable rated for a lower tier (for example, pushing MV packets from an MFE through an LV Copper Cable). Upgrade the cable to the matching tier (such as Gold Cable for MV or HV Cable for HV) or place a Transformer before the cable.
How do I power a low-tier machine with a high-tier cable without placing bulky Transformer blocks everywhere?
Craft a Transformer Upgrade item and place it inside the machine's GUI upgrade slot on the right side. Each Transformer Upgrade increases the machine's maximum input tier by one stage (e.g., from LV to MV).
Does cable length reduce the amount of power reaching my machines?
In standard Tech Reborn configurations, cables do not suffer from distance-based energy loss like older versions of IndustrialCraft did, meaning you can run long power lines across your base as long as the cable's transfer rate matches your packet tier.
By matching generator output tiers to cable capacities and using Transformers to step down packet sizes before they reach lower-tier machines, you can build an efficient, explosion-free Tech Reborn power grid.