NuclearCraft · Late game
NuclearCraft: Overhauled Molten Salt Reactor & Steam Turbine Plant
This late-game NuclearCraft: Overhauled setup integrates a closed-loop Molten Salt Reactor (MSR) with a multi-block Heat Exchanger and a High-Pressure Steam Turbine. Instead of burning solid fuel pellets directly for RF, it circulates molten FLiBe fuel and liquid NaK coolant to boil water into high-pressure steam. You should build this when standard solid-fuel fission reactors no longer meet your base's massive power demands and you want ultra-high thermal efficiency.
- Footprint
- 21x15x9 blocks
- Power
- ~150 kRF/t to 500+ kRF/t (check JEI for exact fuel blend values)
- Throughput
- Continuous closed-loop coolant; ~10 mB/t FLiBe fuel burn
- Difficulty
- advanced
Flow diagram
How items, fluids and energy move through the setup, left to right.
Swipe sideways to see the whole diagram
Materials
| Item | Count |
|---|---|
| Molten Salt Fission Controller | 1 |
| Fission Reactor Casing | 98 |
| Fission Reactor Glass | 36 |
| Fission Fuel Vessel | 12 |
| Fission Coolant Heater (Standard or NaK) | 24 |
| Graphite Block | 18 |
| Fission Vessel Port | 2 |
| Fission Heater Port | 2 |
| Fission Irradiator | 4 |
| Heat Exchanger Controller | 1 |
| Heat Exchanger Casing | 86 |
| Heat Exchanger Glass | 24 |
| Copper Heat Exchanger Tube | 32 |
| Heat Exchanger Inlet | 2 |
| Heat Exchanger Outlet | 2 |
| Heat Exchanger Baffle | 12 |
| Turbine Controller | 1 |
| Turbine Casing | 110 |
| Turbine Glass | 32 |
| Turbine Rotor Shaft | 12 |
| Extreme Rotor Blade | 32 |
| Sic-SiC CMC Stator | 16 |
| Magnesium Turbine Coil | 16 |
| Enderium Turbine Coil | 8 |
| Turbine Rotor Bearing | 2 |
| Turbine Inlet | 1 |
| Turbine Outlet | 1 |
| Salt Mixer | 2 |
| Chemical Reactor | 2 |
| Infinite Water Source | 2 |
| Lithium Ion Battery | 4 |
Build it step by step
1Construct the Molten Salt Reactor Frame
Build a 7x7x7 hollow cube using Fission Reactor Casings for the edges and Fission Reactor Glass for the faces. Place the Molten Salt Fission Controller in the bottom-center of the front face. Install two Fission Vessel Ports and two Fission Heater Ports on the side walls for fluid handling.
2Install Vessels, Moderators, and Heaters
Inside the MSR, place your Fission Fuel Vessels in a symmetrical checkerboard pattern separated by single Graphite Blocks to establish valid neutron flux lines. Surround the vessels and moderators with Fission Coolant Heaters, ensuring every heater satisfies its specific placement rules (check JEI for heater adjacency requirements). Seal the roof to ensure the controller forms properly.
3Set Up FLiBe Fuel Preparation
Place your Chemical Reactors and Salt Mixers near the MSR Vessel Ports. Combine molten Lithium Fluoride (LiF) and Beryllium Fluoride (BeF2) to make a base FLiBe salt, then mix in your fissile fluoride fuel (such as Uranium-235 or LEU-235 fluoride). Pipe this fuel mix into the input Fission Vessel Port and connect the output port to a fluid tank for depleted fuel.
4Build the Multi-Block Heat Exchanger
Construct a 5x5x7 Heat Exchanger frame adjacent to the reactor using Heat Exchanger Casings and Glass, placing the Heat Exchanger Controller on the front. Run two isolated internal pipe networks using Copper Heat Exchanger Tubes and Heat Exchanger Baffles to guide the flow. Configure one inlet/outlet pair for the reactor's NaK coolant loop and the second pair for water-to-steam conversion.
5Prime the Closed NaK Coolant Loop
Connect the MSR's Fission Heater Ports directly to the primary tube loop of the Heat Exchanger. Pump a baseline supply of liquid NaK coolant into the Fission Heater Port until both the reactor heaters and exchanger tubes are filled. Do not turn on the reactor until this loop has enough coolant buffer to prevent immediate overheating.
6Assemble the High-Pressure Steam Turbine
Build a 7x7x10 Turbine frame behind the Heat Exchanger. Run a line of Turbine Rotor Shafts down the exact center axis, anchored at the front and back faces by Turbine Rotor Bearings. Attach 4-way rings of Extreme Rotor Blades and Sic-SiC CMC Stators along the shaft to manage steam expansion.
7Place Dynamo Coils and Connect Steam Lines
On the rear wall of the turbine around the bearing, place your Magnesium and Enderium Turbine Coils according to their placement rules (check JEI for exact coil validation rules). Place a Turbine Inlet on the front face and pipe High Pressure Steam from the Heat Exchanger into it. Place a Turbine Outlet on the rear face to vent Low Pressure Steam into a Condenser loop, returning Preheated Water back to the Heat Exchanger.
8Ignite the Reactor and Balance Flow
Attach a Redstone Control Lever to the Molten Salt Fission Controller and flip it on. Monitor the Heat Exchanger GUI to verify that Hot NaK Coolant is cooling down and boiling Water into High Pressure Steam at a steady 1:1 thermal ratio. Watch the turbine spin up to optimal angular velocity as it fills your Lithium Ion Batteries.
How it works
Unlike solid-fuel fission reactors in the pre-overhaul version of NuclearCraft, the Overhauled Molten Salt Reactor does not produce RF directly. Instead, it acts as a massive thermal furnace. Fissile fluoride salts dissolved in a molten FLiBe carrier fluid enter the Fission Fuel Vessels. When neutrons travel through adjacent Graphite Blocks between vessels, fission occurs, generating raw heat and slowly depleting the fluid fuel.
To prevent a casing meltdown, Fission Coolant Heaters placed inside the core absorb this heat to warm up a liquid coolant—typically NaK (Sodium-Potassium alloy) or a custom eutectic mix. The resulting Hot NaK Coolant is pumped out through Fission Heater Ports into the multi-block Heat Exchanger. Inside the exchanger, the Hot NaK flows past Copper Heat Exchanger Tubes carrying Water (or Preheated Water), transferring its thermal energy to flash-boil the water into High Pressure Steam while cooling back into Cold NaK Coolant to return to the reactor.
Finally, the High Pressure Steam is injected into the front of the multi-block Steam Turbine. As the steam passes through rows of Extreme Rotor Blades and Sic-SiC CMC Stators, the pressure drops and spins the central Turbine Rotor Shaft. The Rotor Bearings transfer this kinetic energy to the valid Dynamo Coils clustered at the end of the turbine, generating hundreds of thousands of RF per tick. Exhausted Low Pressure Steam exits the back, passes through a Condenser, and loops back to the Heat Exchanger as a closed water cycle.
Upgrades and scaling
- Upgrade Copper Heat Exchanger Tubes to Hard Carbon or Thermoconducting Alloy tubes to vastly increase heat transfer speed per block, allowing a much smaller Heat Exchanger footprint.
- Replace basic Uranium FLiBe fuel mixes with high-enrichment Californium or Plutonium fluoride salts to push heat generation higher, driving multiple turbines from a single reactor core.
- Add a second Condenser stage or use Liquid Nitrogen in the Condenser shell to rapidly chill Low Pressure Steam back into Preheated Water at maximum flow rates.
- Chain multiple turbine stages by piping the exhaust of a High-Pressure Turbine into a secondary Low-Pressure Turbine before condensing the steam.
Common mistakes
- Failing to leave space in the NaK coolant loop for fluid movement: If both the MSR heaters and Heat Exchanger tubes are 100% jammed full with zero empty tank buffer, the Hot NaK cannot move and the reactor will melt down.
- Ignoring Dynamo Coil placement rules: Turbine coils in NuclearCraft: Overhauled have strict adjacency dependencies (e.g., needing to touch a specific other coil or bearing). If the Turbine Controller shows an error, check JEI for coil rules.
- Mixing up Fission Vessel Ports and Fission Heater Ports: Pumping NaK coolant into a Vessel Port or FLiBe fuel into a Heater Port will stall the system and force you to break and replace the multiblock ports to clear the internal buffers.
- Using more than the allowed line length of Graphite moderators: Neutron flux can only travel a set number of blocks through moderators before decaying; keep vessels separated by only 1 to 4 moderator blocks.
FAQ
Why is my Molten Salt Reactor forming properly, but producing zero heat?
Ensure that your Fission Fuel Vessels have valid neutron flux paths between them via moderator blocks (like Graphite or Beryllium), and check that you are supplying a valid fissile FLiBe fuel mix and applying a redstone signal to the controller.
How do I stop my turbine from bottlenecking on Exhaust Steam?
If the internal Low Pressure Steam buffer fills up, the rotor stops spinning. Either add a Condenser setup to recycle the exhaust back into water, or attach fluid voiding trash cans to the Turbine Outlet if you are using Infinite Water Sources.
What happens if the MSR overheats?
If the internal heat buffer hits 100% because your Heat Exchanger cannot keep up or ran out of water, the reactor will suffer a meltdown, destroying internal components and spawning radioactive corium blocks.