CC: Tweaked · Late game
Fail-Safe Nuclear Reactor Control Room & Bundled Cable Grid
This late-game control room uses CC: Tweaked, More Red, and Advanced Peripherals to automatically manage a nuclear reactor and prevent catastrophic meltdowns. By continuously reading your main energy bank capacity, the system dynamically throttles reactor control rods to match base demand while conserving fuel. A dedicated fail-safe bundled cable grid provides instant physical emergency shutdown capabilities and visual status alerts across a massive multi-monitor command center.
- Footprint
- 11x9x5 blocks (Control Room only)
- Power
- 0 FE/t (Computers run without power by default, check modpack config)
- Throughput
- 20 ticks/sec telemetry polling & dynamic rod adjustment
- Difficulty
- advanced
Flow diagram
How items, fluids and energy move through the setup, left to right.
Swipe sideways to see the whole diagram
Materials
| Item | Count |
|---|---|
| Advanced Computer | 1 |
| Advanced Monitor | 15 |
| Wired Modem (Full) | 6 |
| Networking Cable | 64 |
| Speaker | 2 |
| Energy Detector (Advanced Peripherals) | 1 |
| Chat Box (Advanced Peripherals) | 1 |
| Redstone Integrator (Advanced Peripherals) | 1 |
| Bundled Network Cable (More Red) | 32 |
| Bundled Cable Relay Plate (More Red) | 4 |
| White Redstone Alloy Wire | 8 |
| Red Redstone Alloy Wire | 8 |
| Orange Redstone Alloy Wire | 8 |
| Green Redstone Alloy Wire | 8 |
| Lever | 1 |
| Redstone Lamp | 6 |
Build it step by step
1Build the Monitor Wall & Command Desk
Construct a 5x3 wall of Advanced Monitors in your control room; they will automatically merge into a single large display screen. Place your Advanced Computer at a desk facing the screen. Attach a Chat Box and two Speakers adjacent to the computer, or connect them later via the wired network.
2Establish the CC Wired Network
Place a Wired Modem (Full) on the back of the Advanced Computer and another on the back of the Advanced Monitor array. Run Networking Cable between them and route the cable line out toward your reactor chamber and main power storage room.
3Connect Reactor and Energy Telemetry
Place an Advanced Peripherals Energy Detector inline with your main energy bank output conduit, and attach a Wired Modem to both the Energy Detector and your energy bank block. Attach another Wired Modem to your reactor's Computer Port. Right-click all modems until their borders turn red to activate the peripherals on the network, taking note of the peripheral names printed in chat.
4Lay the More Red Bundled Cable Grid
Connect a Bundled Network Cable directly to the left side of the Advanced Computer (or to a networked Redstone Integrator). Route this bundled cable to the control desk wall and out to the reactor's Redstone Port. Place Bundled Cable Relay Plates at both ends to break out the individual colored channels.
5Wire the Colour-Coded Channels
At the control desk Relay Plate, connect a Lever using White Redstone Alloy Wire to act as your manual SCRAM switch, and wire Green and Orange Redstone Alloy Wires to Redstone Lamps for status indicators. At the reactor Relay Plate, run Red Redstone Alloy Wire directly into the reactor's Redstone Port (configured to disable the reactor on a high signal) or emergency coolant release valve.
6Program the Proportional Control Loop
Write a Lua `startup.lua` script on the Advanced Computer that wraps the reactor port, energy storage, monitor, and speaker using `peripheral.find()`. Program an infinite `while true do` loop that calculates the energy bank's fill percentage (`getEnergy() / getMaxEnergy() * 100`) and sets the reactor control rod insertion level to match that percentage.
7Configure the Hardware Fail-Safe Routine
Inside the main Lua loop, use `rs.getBundledInput('left')` with `colors.test()` to check if the White channel (manual lever) is active, and poll the reactor's core temperature. If the White channel is active or temperature exceeds critical limits, call `rs.setBundledOutput('left', colors.combine(colors.red, colors.orange))` to force a hardware shutdown, trigger the Speaker alarm, and broadcast a warning via the Chat Box.
How it works
This setup separates high-bandwidth telemetry from critical safety triggers by running two parallel networks: a CC: Tweaked Networking Cable line and a More Red Bundled Network Cable grid. The Networking Cable handles complex data queries, allowing the Advanced Computer to read exact Forge Energy reserves, current FE/t draw via the Energy Detector, fuel depletion rates, and core temperatures. The Lua script uses proportional throttling: as your energy bank fills up from 0% to 100%, the computer gradually inserts the reactor control rods from 0% to 100%. This smooth curve prevents rapid on/off cycling and maximizes fuel efficiency.
The More Red Bundled Network Cable acts as a 16-channel discrete signal highway using CC: Tweaked's `colors` API. While software calls through a Reactor Computer Port are great for fine-tuning, having a physical redstone circuit on the Red channel hooked into a Reactor Redstone Port ensures a guaranteed hardware kill-switch. Meanwhile, the White channel allows an operator to flip a physical lever in the control room to override the computer, and the Green, Orange, and Red channels drive indicator lamps and sirens around the facility without cluttering the walls with dozens of separate redstone dust lines.
Upgrades and scaling
- Add an Environment Detector and Player Detector from Advanced Peripherals to lock down the control room doors and prevent unauthorized players from interacting with the touchscreen monitor.
- Expand the Lua script to manage multiple reactors and steam turbines simultaneously by wrapping peripherals into tables using `peripheral.find()` and balancing load across the grid.
- Place a Wireless Modem or Ender Modem on the Advanced Computer to transmit live reactor telemetry to a Pocket Computer, allowing you to monitor core temperatures and trigger a remote SCRAM from anywhere across dimensions.
- Attach a Redstone Integrator near your coolant production machines and use additional bundled cable colors (such as Blue and Cyan) to automatically turn on auxiliary water pumps when reactor heat rises.
Common mistakes
- Forgetting to right-click the Wired Modems to activate them; if the outer ring on the modem block is not glowing red, the computer cannot see the peripheral.
- Breaking or placing blocks directly adjacent to a connected Wired Modem, which frequently resets its active state and changes its network ID (e.g., from `energy_detector_0` to `energy_detector_1`), breaking hardcoded script names.
- Using `=` instead of `colors.combine()` and `colors.subtract()` when setting bundled outputs in Lua, which accidentally overwrites and turns off all other active color channels on the cable.
- Omitting `os.sleep(0.5)` inside the main monitoring `while true do` loop, which will cause CC: Tweaked to terminate the script with a 'Too long without yielding' error and leave the reactor unsupervised.
- Connecting standard vanilla Redstone Dust directly to a More Red Bundled Network Cable instead of routing through a Bundled Cable Relay Plate and colored Redstone Alloy Wire.
FAQ
Why use both Networking Cables and More Red Bundled Cables?
Networking Cables carry complex peripheral data for fine control and monitors, while More Red Bundled Cables carry 16 color-coded redstone signals in a single block space for physical levers, indicator lamps, sirens, and hardware safety valves.
Which reactor mods are compatible with this control room?
Any reactor mod with native CC: Tweaked peripheral support—such as Bigger Reactors, Extreme Reactors, or Mekanism (Fission Reactor Logic Adapter)—works seamlessly with this setup; check JEI for your reactor's specific computer and redstone port blocks.
What happens if the chunk unloads or the server restarts?
Because the monitoring code is saved as `startup.lua` on the Advanced Computer, it will immediately reboot and resume throttling the moment the chunk loads; just ensure the entire cable network and reactor are chunk-loaded together so peripherals are never missing on boot.