Applied Energistics 2 · Explained · Advanced

Mastering P2P Tunnels and Subnetworks in AE2

Running out of channels and drowning in thick bundles of Dense Cables is a rite of passage for every late-game Applied Energistics 2 player. This guide will teach you how to compress hundreds of channels into a single thin cable using ME P2P Tunnels and how to construct isolated subnetworks with Quartz Fiber to preserve your main network's capacity.

What you need

  • An operational main ME Network with an ME Controller and stable power source
  • ME P2P Tunnels (at least two for a basic connection)
  • A Memory Card for linking tunnels
  • ME Glass Cables or ME Covered Cables (for the carrier subnetwork)
  • ME Dense Covered Cables or ME Dense Smart Cables (for high-capacity routing)
  • Quartz Fiber (for power-only bridging)
  • Cable Anchors (to prevent accidental network merging)

Step by step

  1. 1Place the Input P2P Tunnel

    Walk over to your main ME Controller and attach an ME P2P Tunnel directly to one of its flat faces. Notice that the tunnel has a wide flat side and a smaller rounded tip. The flat side must face into the ME Controller to absorb all 32 channels from that specific controller face.

    Tip: By default, freshly crafted P2P Tunnels are already configured as ME P2P Tunnels, so you do not need to attune them with another item.

  2. 2Build the Carrier Subnetwork

    Attach a standard ME Glass Cable or ME Covered Cable to the small, rounded back end of the P2P Tunnel you just placed. Route this single thin cable all the way to the remote room where you need your channels. Be extremely careful not to let this cable touch any cables from your main network.

    Tip: Place Cable Anchors between adjacent cables or use differently colored cables so your carrier line never accidentally merges with your main network.

  3. 3Power the Carrier Network with Quartz Fiber

    Right now, your carrier cable and the P2P tunnel are offline because the back of a P2P Tunnel does not transfer power from the front. Place a Quartz Fiber between any powered cable on your main network and your new carrier cable. The Quartz Fiber acts as a bridge that allows AE energy to flow into the carrier network while blocking all channels and data from crossing over.

  4. 4Install the Output P2P Tunnel

    At the destination end of your carrier cable, attach a second ME P2P Tunnel. Make sure the small, rounded back end connects to your carrier cable, leaving the wide flat face pointing outward toward the room you want to wire up. Attach an ME Dense Smart Cable to that wide flat face to receive the eventual 32-channel output.

  5. 5Link the Tunnels with a Memory Card

    Equip your Memory Card, return to your ME Controller, and Shift-Right-Click the first P2P Tunnel (the input). This assigns a unique frequency to the input tunnel and saves it to the card. Walk back to your remote destination and simple Right-Click (without holding Shift) the second P2P Tunnel (the output) to bind it to that same frequency.

    Tip: If you are using Smart Cables on your carrier network, you will see two channels light up as soon as the link is established.

  6. 6Distribute Your Remote Channels

    Check the ME Dense Smart Cable attached to your output P2P Tunnel. It now acts as if it is plugged directly into the ME Controller face back at your base, providing 32 fresh channels. You can branch off this dense cable with standard cables to connect your ME Interfaces, Pattern Providers, or storage devices.

  7. 7Scale Up the Carrier Network

    To maximize efficiency, place more input P2P Tunnels on other faces of your ME Controller and connect their backs to the exact same thin carrier cable. Because a standard thin cable acts as an ad-hoc network capable of holding 8 channels, it can support up to 4 Input P2P Tunnels and 4 Output P2P Tunnels simultaneously. This allows you to push 128 channels across your base over a single thin cable.

    Tip: If you need even more channels over a long distance, slap a cheap one-block ME Controller onto your carrier subnetwork to expand its capacity from 8 channels to dozens of P2P pairs.

  8. 8Isolate Storage Using a Subnetwork

    Beyond P2P routing, you can save main network channels by building dedicated storage subnetworks. Connect an ME Storage Bus from your main network facing into the flat panel of a subnetwork's ME Interface, and bridge the two lines with a Quartz Fiber for power. From that single subnetwork ME Interface, run a separate cable to up to 7 ME Drives or other storage blocks; your main network will read all of that inventory while only spending a single channel on its initial ME Storage Bus.

    Tip: Always leave the subnetwork's ME Interface completely empty of config slots; putting items inside its configuration forces it to act as a crafting stock rather than a pass-through inventory.

How it works

To understand why P2P Tunnels are so powerful, you must separate the concept of the data being carried from the hardware doing the carrying. An ME P2P Tunnel is a network device that requires 1 channel to operate, meaning a pair of linked tunnels (one input, one output) consumes 2 channels. However, the tunnels do not consume these 2 channels from the network passing *through* their flat faces; they consume them from the network connected to their rounded backs.

By isolating the backs of the P2P Tunnels onto their own detached cable line—known as the carrier subnetwork—you completely hide the 32 channels flowing inside the tunnel. The carrier cable only sees two devices: an input tunnel and an output tunnel. As long as the carrier cable receives energy via a Quartz Fiber, it remains a completely legal, controller-less ad-hoc network with an 8-channel limit, effortlessly ferrying massive dense-cable payloads across the world.

Similarly, the storage subnetwork trick works because of how an ME Storage Bus interacts with an unpaid, unconfigured ME Interface. An empty ME Interface naturally exposes the entire storage contents of its own network to any external block scanning it. When your main network's Storage Bus looks at the subnetwork's Interface, it sees a single giant inventory chest, completely bypassing the need for the main network to spend channels on every individual drive or drawer controller inside that subnetwork.

Common mistakes

  • Nesting P2P Tunnels: AE2 strictly forbids sending an ME P2P signal through another ME P2P Tunnel. If you attempt to recursively compress your carrier network into another P2P tunnel, the connection will fail to transfer channels.
  • Shift-Right-Clicking the Output Tunnel: Holding Shift while clicking a P2P Tunnel with a Memory Card always overwrites the tunnel as a new Input and resets the frequency. Only Shift-Right-Click the Input tunnel at your controller, and use a normal Right-Click on all corresponding Output tunnels.
  • Forgetting the Quartz Fiber: Because P2P Tunnels do not pass energy from their front face to their back connection, your carrier cable will stay completely dead and display 'Device Offline' unless you bridge power into the carrier line using a Quartz Fiber.
  • Accidentally Merging Networks: If your carrier cable touches a main network cable, the carrier subnetwork ceases to exist and merges into the main network. This immediately causes channel routing chaos and usually shuts down whole sections of your base due to pathing loops.

FAQ

Can I connect one Input P2P Tunnel to multiple Output P2P Tunnels?

Yes, P2P Tunnels support a one-to-many connection by simply right-clicking multiple outputs with the same Memory Card frequency. However, all linked outputs will share the same 32 channels from that single input face rather than duplicating them.

Why does my Output P2P Tunnel say 'Missing Channel'?

This means your carrier network has exceeded its channel limit. If you are using a standard thin cable without a dedicated subnetwork controller, you have likely connected more than 8 individual P2P Tunnel ends (4 pairs) to that single carrier line.

Do devices on the far side of a P2P Tunnel still get power?

Yes. While power does not bleed from the tunnel into the carrier network, energy flows freely through the tunnel itself from the Input face to the Output face, powering all your remote machines and cables.

How much extra energy do P2P Tunnels drain?

Each tunnel has a small passive power draw, plus a minor energy tax based on the items or energy passing through it. You can check the exact AE/t drainage numbers in your in-game guide or by slapping an Energy Cell and a Network Tool onto the system.

By combining isolated carrier networks for ME P2P Tunnels with Quartz Fiber-powered subnetworks, you can route hundreds of channels across your base over thin cables and scale your AE2 infrastructure infinitely without cable spaghetti.

More Applied Energistics 2 guides

Applied Energistics 2 · Getting startedApplied Energistics 2 Getting Started Guide: Meteors, Certus Quartz, and Your First InscriberApplied Energistics 2 transforms your cluttered chest rooms into a sleek digital storage network by converting physical matter into energy. Before you can build your first hard drives and terminals, you must hunt down fallen meteorites, harvest Certus Quartz, and set up your basic processor manufacturing line. This guide walks you through the essential early-game steps to craft your first circuits using the Charger and Inscriber.Beginner8 steps
Applied Energistics 2 · Setup guideHow to Build Your First ME Storage NetworkSay goodbye to rooms overflowing with disorganized chests by building your first Matter Energy (ME) digital storage network in Applied Energistics 2. This guide walks you through setting up an early-game, controller-free network that consolidates thousands of items into a single, searchable crafting interface. Mastering this basic setup is the essential first step toward full base automation.Beginner7 steps
Applied Energistics 2 · ExplainedAE2 Channels, Cables, and ME Controllers ExplainedMastering the channel and cable mechanics of Applied Energistics 2 is essential for scaling your digital storage from a simple chest replacement into a base-wide automation network. This guide will teach you how to manage the 8 and 32 channel limits, utilize color-coded Smart and Dense cables, and properly construct a multi-block ME Controller to prevent network outages.Intermediate7 steps
Applied Energistics 2 · ExplainedME Storage Cells Explained: Bytes vs Types, Partitioning, and Storage BusesMastering Applied Energistics 2 requires moving beyond simply dumping everything into high-tier drives and hoping for the best. This guide breaks down the exact logic behind ME Storage Cell capacities, how to lock drives to specific items using the Cell Workbench, and how to integrate external bulk inventories using the ME Storage Bus. By the end, you will be able to design a lag-free, hyper-efficient storage network that never wastes valuable digital space on cobblestone or damaged mob drops.Intermediate8 steps
Applied Energistics 2 · AutomationHow to Automate Inscribers, Circuits, and Crystal GrowthThis guide walks you through building an automated five-Inscriber sub-network for continuous processor production, along with an infinite Certus Quartz and Fluix Crystal farm in Applied Energistics 2. Mastering these core automation loops eliminates manual crafting bottlenecks and provides the raw materials needed to scale your ME network.Intermediate7 steps
Applied Energistics 2 · Setup guideComplete AE2 Auto-Crafting Guide: Molecular Assemblers, Pattern Providers, and CPUsMastering auto-crafting in Applied Energistics 2 transforms your ME Network from a simple digital warehouse into an automated factory capable of producing complex machinery on demand. This guide will walk you through building Crafting CPUs, configuring Pattern Providers with Molecular Assemblers, and automating external processing machines like furnaces. By the end, you will understand the core logic needed to automate any recipe in your modpack.Intermediate8 steps